NAPCO Gemini GEM-P3200 Installation Instructions Manual page 38

Control panel/communicator
Hide thumbs Also See for Gemini GEM-P3200:
Table of Contents

Advertisement

Page 38
Disable Callback Download See Callback-Method Download
Disable Code Required for EZ Bypass See Selective Bypass (Do not program in UL Installations)
Disable Code Required for Function Mode Level 1
Intended primarily for residential applications, this feature eliminates the user code requirement to access the Function Mode (for
Level-1 Users only), rendering the system more user friendly.
Disable Exit/Entry Urgency Tone
When armed Away, exit is audible, and time is 60 seconds (default). Enabled with "Enable CP-01 Limits" in the EZ Program Menu.
Disable Fire Reset (by Area)
Normally, pressing the
C
for any area, the
C
button will no longer activate the Reset Output so that the integrity of the smoke detector's Alarm Memory
feature (LED indication) will be maintained. Also see Alarm Outputs; Smoke Detectors.
Disable Keypad Function-Mode Download See Callback-Method Download
Disable Openings/Closings
Provides the flexibility of disabling openings and/or closings from any area(s).
Disable Handshake on Transmit (All Formats)
Causes data transmission to start immediately after the telephone number.
Disable Wait-for-Silence (Pager Format)
Causes data transmission to start immediately after the pager telephone number.
Double Reporting See Report Telco 3
Download Security Code See Master Security Code
Download To an Armed Panel
This allows the panel to accept a download even if Armed. However if the programming to be altered effects the arming profile of
the control, such as zone features, it is recommended that the panel be disarmed and then rearmed to allow these changes to be
processed properly. Any program changes such as adding/changing user codes, adding users to an area, or changing Entry/Exit
Delays will be processed properly with the panel armed.
Don't Clear Aux. Relay with Arm/Disarm
Used in conjunction with Key-Fob Option "C" above to prevent a disarm from resetting the Aux. Relay.
"E" Lugs (E3, E5, E7, E9, E10, E11, E14, E18, E19, E22)
E9 - See Fire Lug
E10 - See Burglary Lug
E19 - See Veri-Phone: Silence All Outputs During Audio Session
E22 - Common terminal for Reset Relay. Use Napco Part No. WL1 for field wiring.
Easy Arming
Permits quick arming by simply pressing the
grammed for Easy Arming (see Keypad Features). Disarming still requires entry of a valid user code. Do not program Easy Arming
in UL installations. If closings are reported, Easy Arming will report as User 99.
Easy Exit (Not Evaluated by UL)
While armed in the Interior Bypass/Stay Mode, Easy Exit can be initiated by pressing
allowing a User to exit an armed premises without disarming and rearming the system.
Easy Setup for RF Only
Removes all EZMs automatically programmed in the menu-driven Keypad Program Mode. This must be the last step in the pro-
gramming menu. Access Location 4090, then press the
Enable All-Zone-in-Trouble Bypass
If programmed, all zones in trouble (except Fire and PIR Zones) that are also programmed for Selective Bypass will be by-
passed.
Enable Bell On Exit Error (SIA CP-01 Requirement: 4.2.2.4)
An Exit Error sequence is initiated if an entry/exit zone is violated at the expiration of the Exit Time. An Exit Error is processed
as follows:
1. The local alarm shall immediately sound.
2. The keypad annunciator sounds an Entry Delay.
3. An Entry Delay is initiated.
4. If the alarm system is not Disarmed at the end of the Entry Delay, the Alarm Transmission Sequence is initiated.
5. The Alarm Transmission includes the alarm and an Exit Error.
X
GEM-P3200 Installation Instructions
button will momentarily remove power to the smoke detectors. If Disable Fire Reset is selected
or
P
Q
J
U
or
button for 2 seconds. Each keypad may be individually pro-
J
or
button.
L
WI817F 10/05
U
. Easy Exit restarts the Exit delay,
NAPCO Security Systems

Advertisement

Table of Contents
loading

Table of Contents