Arcconf Playconfig - Adaptec CDP-00276-01-A User Manual

Raid controller command line utility
Table of Contents

Advertisement

TO
Indicates that the modifications will follow
Options:
• Stripesize—indicates the stripe size in KB. Options are 16, 32, 64, 128, 256, 512, and 1024. the default
is 256KB.
• init_priority—is the priority level of the modification. Options are low, med, and high.
• Legs— is the number of subarrays for a RAID level-50 or RAID level 60 array. Possible values are 2-16
legs and 3-16 drives/leg (to 48 drives maximum).
Size is one of the following values:
• MAX indicates that you want to use all available space on the disk.
• Desired size in MB.
RAID# is the RAID level for the logical drive 0, 1, 5, 5EE, or 10.
Note: The CHANNEL# and DRIVE# parameters is the list of devices that will contain
the target modification object. Channel and device_ID are repeatable parameters.
Channel# is the channel number for the device.
Drive# is the device_ID (device number) for the device.
Noprompt is an optional parameter that overrides the user prompt.
Example
ARCCONF MODIFY 1 FROM 2 TO 2048 0 0 123 0 124 0 117

arcconf playconfig

Description
Configures a controller using a XML server template file produced by the SAVECONFIG command (see
arcconf playconfig
on page 28). Use this command to deploy the same controller configuration on
multiple servers in your storage space.
Note:
1. The XML server template file (default, saveconfig.xml) is editable. For example,
you may need to change the disk drive capacity, logical drive size, or RAID level.
2. Drives from the same vendor with slightly different capacities (147GB vs 150GB,
for instance) are considered interchangeable. If the interchange results in a change
in logical drive capacity, the drive is scaled, as needed. For example, if the new
drives have 4% more capacity due to vendor or model changes, then all logical
drives are increased in size by 4%.
3. Be sure to check the log file to verify that the controller was configured successfully.
The exit codes, shown below, indicate the success or failure of the operation and
if the system needs to be rebooted.
Code
SUCCESS
FAILURE_GENERAL
SUCCESS_REBOOT
Syntax
ARCCONF PLAYCONFIG <Input XML File> [LogFile] [FORCE ALL|LOGICALSIZE]
Proprietary and Confidential to PMC-Sierra, Inc.
Document No.: CDP-00276-01-A Rev. A, Issue:
Adaptec RAID Controller Command Line Utility User's Guide
Value
Meaning
0
Configuration succeeded, no reboot is
required.
1
An error occurred and the configuration
could not be completed.
2
Configuration succeeded, but a reboot is
required.
28