5.3.4
REAL-TIME CLOCK
^A
^D
Command
30
Change Clock: Use the sequence below to set the time and date of the optional
real-time socket:
^D305
HH:MM:SS5
DD/MM/YY/W5
HH = hours (24 hour format)
MM = minutes
SS = seconds
The clock produces a string of text that is accessed through use of a TSN of 0 (See
table 9 for definitions of field parameters).
The text string is shown below...
...where xxx is the day of the week.
These values should be inserted into the Field parameters for proper clock text access:
TSN
W = day of the week
1 = SUN
2 = MON
3 = TUE
4 = WED
5 = THR
6 = FRI
7 = SAT
HH:MM:SS MM/DD/YY XXX DD/MM/YY XXX
Clock Field Parameters
TSP
0
1
0
10
0
19
0
23
0
32
MM = month
DD = day of month
YY = last 2 digits of
CC
8
HH:MM:SS
8
MM/DD/YY
3
Day of Week
8
DD/MM/YY
3
Day of Week
Table 9
50
year
TEXT
Need help?
Do you have a question about the 465 and is the answer not in the manual?
Questions and answers