^A
^D
COMMAND
23
Change SW3: Software dip switch #3. Below is the ^AB sequence:
12345678
^ABxxxxxxxx
*******.)
******.)
*****.))
****.)))
***.))))
**.)))))
*.))))))
.)))))))
Position:
1
Piezo Sound: If set to 1, the piezo is disabled.
2
Not Used
3
Response After Print: If enabled, an enquiry response will be sent back through
the communications port after every print.
4
Head Up Error: If set to 1, head up error checking is disabled.
5
Pulse Tone On Piezo: If set to 1, the piezo is disabled.
6
Ribbon Break Sensor: If disabled, no error will occur if ribbon is out.
7
Not Used
8
Not Used
Not Used
Not Used
1=Ribbon Break Sensor Disable, 0=Enable
1=Pulse Tone On Piezo, 0=Continuous
1=Head Up Error Disable, 0=Enable
1=Response After Print Enable, 0=Disable
Not Used
1=Piezo Sound Disable, 0=Enable