XX
76
Load Delay Time Between Labels: Preceded by ^A which contains the wait in
1/10ths of a second. Maximum value is 650.
80
Disable all serial numbering.
XX
81
Disable Single Serial Number Field: Will disable an individual serial number
field.
XX
82
Enable Single Serial Number Field: Will recall a stored serial number (1-16) and
place it into an individual serial number field on the label. XX determines the stored
serial number slot to be recalled. The TSN (Text String Number) is selected by
following the ^AXX^D825 with the TSN surrounded by quotes ("TSN"5). This
command is not stored between different labels, it must be sent each time a format
is sent and must be located after the ^D57 command and format information.
XX
83
Select Stored Serial Number to increment: Tells the printer which stored serial
number to increment. See section 4.5 on text string numbers. The ^A value states
which serial number is selected.
XX
84
Select Stored Serial Number to decrement: Tells the printer which stored serial
number to decrement. See section 4.5 on text string numbers. The ^A value states
which serial number is selected.
85
Clear All Stored Serial Numbers: This function will erase any serial numbers
stored in memory.
XX
86
Load New Serial Number Into Memory: This command loads a serial number
into non-volatile memory. XX is used to select the serial number slot (1-16). The
actual serial number, up to 9 characters, is placed in quotes and follows the
^AXX^D865.
XX
87
Load Increment/Decrement Value Into Memory: Will load and store a step
value into non-volatile memory. The stored serial number to be affected is chosen
with the XX variable and the actual step value, up to 9 characters, is entered by
following the ^AXX^D875 with the step value surrounded by quotes.
92
Need help?
Do you have a question about the 465 and is the answer not in the manual?
Questions and answers