Setting The Maxcache Flush And Fetch Rate; Verifying And Fixing The Maxcache Container - Adaptec CDP-00278-02-A User Manual

Maxview storage
Table of Contents

Advertisement

• Enter a name for the maxCache Container. Names can include any combination of letters and
numbers, but cannot include spaces.
• Set a smaller logical drive size. (By default, the maxCache Container uses all available drive space.)
• Set the build method to: Build, Clear, or Quick.
• Set the build priority to: High, Medium, or Low.
See
Fine-tuning Logical Drives
Attributes panel.
7. Click Next, then review the logical drive settings. To make changes, click Back.
8. Click Finish.
maxView Storage Manager builds the maxCache Container. Use the Event Log and Task Log to track
build progress.

Setting the maxCache Flush and Fetch Rate

Once the maxCache Container is built, you can set its Flush and Fetch rate to optimize the read cache
performance.
To set the maxCache Container Flush and Fetch rate:
1. In the Enterprise View, select a controller, then select the associated maxCache Container.
2. On the ribbon, in the maxCache group, click Set Properties.
The Set Properties window opens.
3. In the drop-down list, set the Flush and Fetch rate to: Slow, Medium, or High. The default is Medium.
Note: The lower the rate, the longer data is kept on the maxCache Container
before it's flushed from the cache.
4. Click OK.

Verifying and Fixing the maxCache Container

If maxCache is enabled for a controller, you cannot complete any other tasks on that controller while
maxView Storage Manager verifies and fixes the maxCache Container. Optionally, you can choose to
verify the maxCache Container without fixing inconsistent or bad data, or run a coherency check to
compare valid pages of the maxCache Container with their corresponding logical drive storage.
To verify and fix the maxCache Container:
1. Ensure that no activity is taking place on the controller for the maxCache Container.
2. In the Enterprise View, select the maxCache Container you want to verify and fix.
3. On the ribbon, in the maxCache group, click Verify.
The Verify maxCache window opens.
4. Choose a verification option:
Proprietary and Confidential to PMC-Sierra, Inc.
Document No.: CDP-00278-02-A Rev. A, Issue:
on page 55 for details about customizing the settings in the RAID
maxView Storage Manager User's Guide