Parameter Table
Table 10-1
List of the parameters of SICLOCK TC 400
1)
Access
Parameter
/ No.
Ethernet 2
0.15.02
Ethernet 3
0.15.03
Ethernet 4
0.15.04
NTP Server
NTP Server
0.16.01
Multicast[4]
0.16.02
10-92
Entry
mode
send condition
destination address
mode
send condition
destination address
mode
send condition
destination address
operation
mode
multicast address
Value Range / Default
Min:
off
Max:
S5-compat., every 10 s
Default:
off
Min:
---
Max:
only if synchronized
Default:
---
Min:
00.00.00.00.00.00
Max:
FF.FF.FF.FF.FF.FF
Default:
FF.FF.FF.FF.FF.FF
Min:
off
Max:
S5-compat., every 10 s
Default:
off
Min:
---
Max:
only if synchronized
Default:
---
Min:
00.00.00.00.00.00
Max:
FF.FF.FF.FF.FF.FF
Default:
FF.FF.FF.FF.FF.FF
Min:
off
Max:
S5-compat., every 10 s
Default:
off
Min:
---
Max:
only if synchronized
Default:
---
Min:
00.00.00.00.00.00
Max:
FF.FF.FF.FF.FF.FF
Default:
FF.FF.FF.FF.FF.FF
Min:
on
Max:
only if synchronized
Default:
on
Min:
off
Max:
60 s with local time
Default:
off
Min:
0.0.0.0
Max:
255.255.255.255
Default:
0.0.0.0
© Siemens AG 2007 All Rights Reserved