Authorization - Siemens SICLOCK TC 400 Operating Instructions Manual

Plant central clock
Table of Contents

Advertisement

Configuration Tool
7.2.2

Authorization

There are authorization levels for each parameter, which permit or prohibit read
and write access to the parameter. The user interface starts with the lowest autho-
rization level, which usually only permits read access to parameters.
More rights can be obtained by entering the appropriate password.
The password can be changed by the user:
• /System/Authorization For Standard Protection (2.06.02) parameter
As delivered, the password on the device is "2222"
The current authorization level is indicated by the color of the password field.
Write protection - red entry field
At this authorization level, the user typically only has read access to standard
parameters.
Standard protection - green entry field
At this authorization level, the user typically also has read access to advanced
parameters and write access to standard parameters.
Online mode
Authorization is performed directly on the device, i.e. the device assigns an
appropriate authorization level.
Offline mode
You can authorize yourself for a higher authorization level with a password, when
this is contained in the loaded offline authorization parameters.
Note
It is not possible to authorize yourself in offline mode with a password that is avail-
able on the device, but is not contained in the offline authorization parameters.
7-52
© Siemens AG 2007 All Rights Reserved
SICLOCK
®
TC 400

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents