$. MAINTENANCE

1. Removing the rear cover

WARNING :
To prevent personal injuries caused by electric shock hazards or abrupt start of the sewing machine,
remove the cover after turning OFF the power switch and a lapse of 5 minutes or more. To prevent
personal injuries, when a fuse has blown out, be sure to replace it with a new one with the same
capacity after turning OFF the power switch and removing the cause of the blown-out of the fuse.
3
3) Loosen setscrews 2 n front cover 1 .
4) Open front cover 1 whle pressng latch 3
located on the sde face.

2. Replacing the fuse

1
3
2
1
1) Press the OFF button of the power swtch to turn
OFF the power after confirming that the sewing
machne has stopped.
2) Draw out the power cord comng from the power
plug socket after confirming that the power switch
is turned OFF. Perform the work of step 3) after
confirming that the power has been cut and it has
passed for 5 mnutes or more.
6
5) Loosen two screws 5 after loosenng screw 4 ,
and remove rear cover 6 . When attachng rear
cover 6 , tghten two secrews 4 after lghtly en-
terng screw 4 , and tghten screw 4 agan.
1) Hold the glass secton of the fuse 1 and remove
t.
2) Use the fuse of which capacity is specified.
1 : 3.15A/250V tme-lag fuse
(Power crcut protecton fuse)
Part No. KF000000080