Pci Slot Locations And Configurations; Removing The Scsi Core I/O Card; Scsi I/O Card Latch Location - HP Integrity rx4640 Service Manual

Hide thumbs Also See for Integrity rx4640:
Table of Contents

Advertisement

PCI Slot Locations and Configurations

PCI slots are numbered from 1 through 8 in the server.
locations on the I/O baseboard. The dedicated core I/O card slots are slots 1 and 2.
The following describes configuration requirements for slots 1 and 2:
PCI slot 1 is dedicated for use by a SCSI HBA card. Slot 1 is not hot-plug capable. Additional
PCI expansion cards may not be placed in slot 1.
PCI slot 2 is dedicated for use a LAN card. Slot 2 is not hot-plug capable. Additional PCI
expansion cards may not be placed in slot 2.

Removing the SCSI Core I/O Card

To remove the SCSI core I/O card in slot 1, follow these steps:
1.
If rack mounted, slide the HP server out from the rack until it stops. See
Server From the Rack" (page
2.
Remove the top cover from the chassis. See
3.
Disconnect any internal and external SCSI cables connected to the SCSI core I/O card.
4.
Open the blue PCI card latch for slot 1 by twisting it clockwise.
Figure 4-31 SCSI I/O Card Latch Location
5.
Remove SCSI I/O card by pulling up carefully on the SCSI I/O card.
Figure 4-30
31).
"Removing the Top Cover" (page
Removing and Replacing Core I/O Cards
shows the core I/O card
"Extending the
36).
73