noft Diagnostic Messages
*** DATA ERROR *** [1048]:
Unable to reset option, please reset manually.
Cause.
FILE or F
SCOPEPROC, SET SCOPESOURCE, and SET CASE to their defaults.
Recovery. Use
(or all of the SET parameters) to their defaults and then enter the desired new option
value.
*** DATA ERROR *** [1049]:
Unable to retrieve [first|second] timestamp.
Cause. The first or second timestamp of the source files is unavailable.
Recovery. Ensure that the source files are not corrupt.
*** DATA ERROR *** [1050]:
Unable to scan instructions.
Cause. noft cannot find an instruction for the opcode at this address.
Recovery. Ensure that noft is looking at a code section with ICODE.
*** DATA ERROR *** [1051]:
Unable to understand that [directory |
[\<node>.][$<volume>.][<subvolume>] ]
Cause. One of the following has an invalid format:
The directory (pathname) specified by
The system (node-name) or subvolume-name specified by
VOLUME
on page 5-48
Recovery. Ensure that the specified directory, system, or subvolume exists and has
the correct format.
on page 5-15 encountered a problem when trying to SET
RESET
on page 5-41 to reset SCOPEPROC, SCOPESOURCE, and CASE