You can start IP-900E/IP-900D series by turning on the power while holding down the [MNT]
Button (for about 10 seconds) until the RDY LED begins blinking in orange. Doing so starts the
IP-900E/IP-900D series with the initial IP address and subnet mask with which the IP-900E/
IP-900D series is shipped from the factory (IP address 10.0.0.1, Subnet mask: 255.0.0.0).
Use this function when making initial settings for IP-900E/IP-900D series from a control
terminal (such as a PC having a LAN interface) (*1).
*1 When you operate the IP-900E/IP-900D series with the default IP address, connect the device
to a control terminal and make setting from the terminal with the device disconnected from
your network.
After making settings according to the requirements for your network, connect the device to
the network. If the device with the default settings made at the factory is connected to the
network, an unexpected problem may occur with your network.
If you start IP-900E/IP-900D series while holding the [MNT] button, set the IP addresses and
subnet masks of the control terminal to connect as follows:
- IP address
(xxx is any number from 0 to 255, excluding 10.0.0.0, 10.0.0.1, and 10.255.255.255.)
- Subnet mask
IP-900E/IP-900D series

Special Use of MNT Button

: 10.xxx.xxx.xxx
: 255.0.0.0
40