Chapter 3 Operation instructions
Error Code.
Error information
0001
Boot (Power On)
0002
Boot (Reset)
0006
Software update
0007
Boot (Restart)
0008
Boot (Others)
0009
Shutdown
000A
RTC initialization
000B
CF card initialization
000C
Configuration update
L001
LINK error(LAN)
L002
LINK error (CONSOLE)
L006
Time server synchronization failure
L009
DHCP connection failure
L00A
PPPoE connection failure
L00C
IP address collision
L00E
DHCP connection update
L00F
PPPoE connection update
I001
HD-SDI input down
I002
HDMI input down
I005
DVB-ASII input down
I006
Reference clock input down
I011
Video synchronization error
I015
DVB-ASI synchronization failure
I016
Reference clock synchronization failure
E001
Power error (*1)
E003
Temperature error occurrence (*5)
E00A
Flash ROM check sum error (*1)
E010
FAN1 error (*2)
E011
FAN2 error (*2)
E013
Temperature warning (*2)
E082
CODEC1 error (*4)
E083
CODEC2 error (*4)
E084
CF card access error (*3)
E085
CF card power error (*3)
E08B
SUBCPU 1 error (*4)
E08C
SUBCPU 2 error (*4)
E08E
Clock error (*1)
E08F
Memory error (*1)
E090
Downconversion error (*6)
E091
Intercom error (*4)
E092
Version mismatch (*3)
E0A1
Optional card error (*3)
E0A4
Optional card (Unequipped) (*7)
"*" is marked on the left side of an error code for which an alarm recovery has occurred.
*1 After an alarm occurs, the ALM LED remains on. The device needs to be rebooted to turn off the ALM LED.
*2 The ALM LED blinks while an alarm is active. The LED goes off when the alarm cause is recovered.
*3 After occurrence of this error, the ALM LED remains to blink.
*4 After occurrence of this error, the operation is retired for recovery. If the retry for recovery is unsuccessful,
the ALM LED remains on. The device needs to be rebooted to turn off the ALM LED.
*5 If an extreme temperature is detected, all LEDs except LINK/ACT, 100/1000 go on. The device needs to be
rebooted to turn off the LEDs.
*6 The ALM LED is on while this alarm is active. The LED goes off when the error cause is recovered.
*7 The ALM LED blinks on while this alarm is active. The LED goes off when the error cause is recovered.
IP-9500e
Alarm codes
Description
Normally started by the power button
Normally started by reboot
Software updated
Restarted due to a CPU error
Restarted due to a software error
Shutdown by LCD operation
RTC battery backup failure
CF card formatting error
Configuration data updated
Disconnected from network equipment
Disconnected from network equipment
Time synchronization with the time server failed
Disconnection recognized by DHCP
Disconnection recognized by PPPoE
Collision between IP addresses on LAN and CONSOLE
IP address changed during DHCP connection
IP address changed during PPPoE connection
HD-SDI input signal not detected
HDMI input signal not detected
DVB-ASI input signal not detected
GENLOCK signal not input
HD-SDI signal synchronization failed
DVB-ASI signal synchronization failed
GENLOCK input PLL synchronization failed
Power failure occurred
Abnormal temperature (shutdown processing started)
Invalid data set in built-in Flash ROM
FAN1 failed (low speed) or stopped
FAN2 failed (low speed) or stopped
Temperature alarm caused (warning only)
HD CODEC LSI error occurred
SD CODEC LSI error occurred
Access to the CF card failed
Over current to the CF card occurred
SUBCPU 1 error occurred
SUBCPU 2 error occurred
Clock error or disconnection occurred
SDRAM memory check error occurred
Video Scalar error occurred
Intercom error occurred
Version mismatch between hardware and software
Optional card failure
Optional card unequipped
38