PL38DF* Indoor Gas Fireplace NOTICE You must read and understand this manual prior to installation, operation or troubleshooting this appliance. Please retain this owner’s manual for future reference and maintenance. Table of Contents Section 6: Finishing Instruction Manual Contents Section 7: Screen Installation and Removal Safety Alerts Section 8: Installing &...
Introduction Congratulations on your purchase of a Montigo Fireplace. With over 35 years of experience, Montigo is committed to providing you with a gas fireplace that is not only a beautiful addition to your space, but that is also designed and manufactured to the highest safety, reliability and engineering standards.
See Section 1, Dimensions on Page 7, and refer to the The PL38DF* Direct Vent fireplace must be installed in accordance Framing Section 2 on Page 8 for details. with these Instructions. Carefully read all the Instructions in this Select the location of your termination and resulting vent run.
PL38DF* Indoor Gas Fireplace Installation Standard Installation Checklist This standard installation checklist is to be used by the installer in conjunction with, not instead of, the instructions contained within this installation manual. Customer Date Installed: Install Address: Location of Fireplace:...
The rating place may be found under the firebox. To access, remove the screen and valve cover. See Section 7: Screen Installation and Removal and Section 8: Installing & Removing the Door. Figure A: Rating Plate for PL38DF-F IPI Electronic Ignition Page 6 XG0216 - 160215.1...
Direct Vent installation. The PL38DF* fireplace may be installed in any location that maintains proper clearances to air conditioning ducts, electrical wiring and The fireplace dimensions are shown below: plumbing.
PL38DF* Indoor Gas Fireplace Installation Section 2: Framing The install size requirements of your fireplace are dependent on Combustible Header several factors. Gas line location, electrical connection, gas line Combustible Shelf Non Combustible type and decorative surround options can play into the install sizing.
Figure 7b. Insert folded tabs into slots above the front of the fireplace †† Four sided surrounds require a raised installation. Installing The Standoffs To avoid elevated mantel temperatures, all PL38DF* gas fireplaces are required to have the supplied standoffs installed. The fireplace is supplied with two standoffs. Bend and install these standoffs on top of the fireplace ensuring that the height of the 4"...
Section 3-1: Converting to Rear Vent Use the following instructions to convert an PL38DF* for Rear Vent use: 1. Remove the Rear flue cover and gasket (5" and 8") on the flue outlet, as shown in Figure 8.
PL38DF* Indoor Gas Fireplace Installation Section 3-2: Installing a Roof Mounted Direct Vent PVTK1 Termination (PVTK-1) Termination This section applies to installations where the direct vent termi- 2’ min. nation will be roof mounted. Support ring Section 3-2-1: Venting Layout...
Page 12
PL38DF* Indoor Gas Fireplace Installation PVTK1 Termination PEXT Sections Support plate 32’ max Support ring 12” Max. Figure 9c. Rear vent, Roof mounted venting (1 = 90° bend). Note: Images are shown without screens for clarity purposes. However, your fireplace should not be operated without proper installation of screens.
PL38DF* Indoor Gas Fireplace Installation Section 3-3: Installing a Wall Mounted Direct Vent 4). Installation of termination from inside structure Termination A Termination with a MOSR Frame is installed from the inside of the structure. These are commonly used in high-rise construction.
Venting runs must fall within the limits set by the venting graph, see Figure 12 or 12a. Figure 12a. PL38DF* NG Top Vent Venting Graph for wall mounted Wall mounted Terminations terminations. The following details are some possible configurations for Wall mounted terminations.
Page 15
However, your fireplace should not be operated without proper installation of screens. IMPORTANT: Corner Installation is available for PL38DF Top Vent Units Only. Ensure minimum Vertical Venting Height of 40" is maintained in corner installations. Page 15 XG0216 -160215.1...
Page 16
PL38DF* Indoor Gas Fireplace Installation Notes Wall Mounted Terminations: REAR VENT ■ All dimension lengths for vertical or horizontal runs are Acceptable vent run measured from center of the vent pipe. within non-shaded area. ■ Venting runs must fall within the limits set by the venting graphs, see Figure 15 or 15a.
PEXT - 3 (36" f/m Section) any possible hot spots. PEXT - 4 (48" f/m Section) Montigo recommends the use of a flex section for the final PEXT - 6 (72" f/m Section) pipe connected directly to the fireplace offering greater E - Elbows PEL-90MM (m/m 90º...
PL38DF* Indoor Gas Fireplace Installation Section 3-3-3: Heat Shields Installing a Wall Mounted RHS101 Heat shield. The RHS101 Heat shield MUST be used where the RHS8 Termination Installing a Wall Mounted RHS8 Heat shield (Figure 17 and 17a) CANNOT be used. Use the RHS101 where any The RHS8 Heat shield CANNOT be used when the Termination is of the dimensions are within the parameters shown, figure 17a.
WHITE LED Lights LED1 - Red LED LED2 Amber LED Figure 19. Wiring diagram for PL38DF with SIT Proflame 2 Electronic Ignition 2 " 7 8 " NOTE: If any of the original wire supplied with the appliance is 2 "...
PL38DF* Indoor Gas Fireplace Installation CPI [Continuous Pilot Ignition] / IPI [Intermittent Installing the CPI Jumper Cable Pilot Ignition] Jumper Cable Installation 1). Remove the door and valve blind. “Why use CPI mode”? There are several reasons why you may choose to use CPI mode.
1/8” N.PT. plug to be fitted with a hose Figure 22. Gas line access. barb. Montigo requires a service shut off valve be located in an accessible location to isolate the gas supply. WARNING Only install gas shut-off valves approved for use...
PL38DF* Indoor Gas Fireplace Installation Section 6: Finishing Mantels & Surrounds NOTE: National Canadian Gas Association mantel test requirements Finishing Around the Fireplace are for fire hazard prevention to combustible materials. Non-combustible mantels and mouldings may be safely installed New technology, to meet consumer and government demands for the...
PL38DF* Indoor Gas Fireplace Installation Section 7: Screen Installation and Removal Left Side Detail Upper Screen Studs Upper Screen Removing / Attaching Screens: Stud Catch To R To Remove Screens: Grasp each top outer corner of the screen with your thumb and finger and pull towards yourself.
Installation Section 8: Installing & Removing the Door Removing the door: The PL38DF* doors are removed in a few simple steps. Follow these instructions below to remove the Horizontal access panel, unlatch Step 4: the door buckles and, remove the door. Replace in reverse order.
Page 25
PL38DF* Indoor Gas Fireplace Installation Step 8: Removing the Door: Grasp the Door on either side, usually midway and lift upward, lift the door carefully up and away from the front of the fireplace. See Figures 25g. Place the Door aside in a safe place while maintenance and / or cleaning is being performed.
Installation Section 9: Installing the Accessories Installing the Firestones The PL38DF* is supplied with firestones. Remove the Door as shown in Section 8. Follow these instructions to ensure all parts are removed or replaced as required. Once the Trim and glass door is removed place the firestones in a single layer across the pan and the burners as described in Figure 26 to 26d.
Figure 26f. Ensure the stones DO NOT cover the pilot. WARNING: This appliance is intended for use only with the included Montigo burners and accessories. Never install or add any additional or alternative media, rock wool or other material in this appliance.
Page 28
PL38DF* Indoor Gas Fireplace Installation Installing Optional Driftwood Log Set The PL38DF* has the option of installing a driftwood log set. Once the firestones or speckled stones have been installed the log set can be installed. Ensure logs are securely placed and will not tip or fall. Remove media where logs touch the burner tray to ensure a more secure position.
Page 29
PL38DF* Indoor Gas Fireplace Installation Step 9. Place log 1 from LGS59 on top of log 4 from Step 7. Place log 5 from LGS59 in the back left corner LGS58. Place log 6 from LGS58 on top of log 4 from of the burner, behind the pilot.
PL38DF* Indoor Gas Fireplace Operation Operation For Your Safety - READ BEFORE LIGHTING: with American Flame Electronic Ignition WARNING If the information in these instructions is not followed exactly, a fire or explosion may result causing property damage, personal injury or death.
PL38DF* Indoor Gas Fireplace Operation Remote Operation The Proflame 2 System consists of the following elements: Blue Back lit LCD display 1. Pilot Assembly 2. Proflame Gas Valve. 3. Proflame 2 Control Module On/Off Key Thermostat Key 4. Wiring Harness Up/Down Arrow Key 5.
Page 32
PL38DF* Indoor Gas Fireplace Operation Temperature indication Display Initializing the System for the first time 1. Set master override switch to off position. With the system in the "Off" position, press the Thermostat Key and the Mode Key at the same time. Look at the LCD screen on 2.
Page 33
PL38DF* Indoor Gas Fireplace Operation Remote-Flame Control Room Thermostat (Remote Control ....... Operation) When you turn on the fireplace it starts on high. The proflame 2 has six (6) flame levels. Each time you press the Down Arrow Key once the flame height will reduce by one step.
Page 34
PL38DF* Indoor Gas Fireplace Operation Disabling Thermostat Fan Speed Control (OPTIONAL) Some jurisdictions and bedroom installations require the The fireplace is equipped with optional hot air circulating fans. thermostat to be disabled. The speed of the fans can be controlled by the Proflame system.
Page 35
PL38DF* Indoor Gas Fireplace Operation Continuous Pilot (CPI) Selection (Optional) Low Battery Power Detection In cold weather climates, the pilot burner can stay on The life span of the batteries depends on various factors: quality continuously to prevent condensation or cold air temperatures of the batteries used, the number of ignitions of the appliance, near the fireplace glass.
PL38DF* Indoor Gas Fireplace Maintenance Maintenance General Pilot Burner Adjustment. Have the fireplace and installation inspected yearly. The inspection 1. Locate Pilot Adjustment Screw. (See figure 29) must include, but is not limited to, the following: 2. Adjust pilot screw to provide properly sized flame as shown.
If your fireplace still does not operate correctly, consult your local Montigo dealer. All service and repairs should be performed by a qualified Technician. All spare parts, optional fans, and optional trim finishes are available from your local Montigo dealer. Page 37...
PL38DF* Indoor Gas Fireplace Appendix Replacement Parts: Replacement Parts List - SIT IPI Proflame 2 PL38DF NG Gas Valve (with stepper motor) RGC3033 LP Gas Valve (with stepper motor) RGC3034 NG Pilot Assembly RPA035 LP Pilot Assembly RPA036 Ignitor Probe Assembly...
PL38DF* Indoor Gas Fireplace Appendix Appendix A: Venting Terminations Location Canada* USA** clearance to the termination frame above grade, veranda, porch, deck, or balcony 12 inches 12 inches clearance to top of doors or operable windows 12 inches 12 inches...
The duration of any implied warranty with respect to this Montigo Gas Appliance is limited to the duration of the foregoing warranty. Some states do not allow limitation on how long an implied warranty lasts, so the above may not apply to you.
PL38DF* Indoor Gas Fireplace Appendix Appendix C: State of Massachusetts Amendment (Gas Fireplace / Equipment sold in the State of Massachusetts) 5.08: Modifications to NFPA-54, Chapter 10 (1) Revise NFPA-54 section 10.5.4.2 by adding a second exception as follows: Existing chimneys shall be permitted to have their use continued when a gas conversion burner is installed, and shall be equipped with a manually reset device that will automatically shut off the gas to the burner in the event of a sustained back-draft (2) Revise 10.8.3 by...
Page 42
PL38DF Single Sided Gas Fireplace XG0216 - 160215.1...