WIRING DIAGRAM
FOR 230V APPLICATION
The unit is default 230V, if volt free application is
required you must remove link & follow diagram
below.
SL (Off)
- Heat Off
L
- Live
SL (On)
- Heat On
N
- Nuetral
It is vital to connect the live into this terminal to
avoid overloading of the jump wire.
WIRING DIAGRAM
FOR VOLT FREE APPLICATION
(Remove Link!!!)
The unit still requires a 230V feed for V.F.
applications
L
- Live (230V Feed)
N
- Nuetral
NC
- Normally Closed
COM
- Volt Free Feed
NO
- Switched Live (Volt Free)
SETTING OF CONTROL CENTR
Heater/Cooler Selection
Before making any selection in the
control centre, its back housing must
be removed as follows :
Inside the Control Centre after back
housing is removed, you can find the
DIP switch. These three switches are
used to control the span and
heat/cool system. Set the DIP switch
(position 3) according to your
selection of heater
system or cooler
system as the following
diagram.
Temperature Span Selection
Span is the temperature difference between
on temperature and turn off temperature. F
ple, in heating systems, if you set temperat
12
13
Remove
the front
housing
Set the DIP switch (pos