Fieldserver As A Weigh-Tronix Client; Hardware Connections; Setting Up The Scale - FieldServer Weigh-Tronix FS-8700-36 Driver Manual

Fieldserver technologies computer driver instruction manual
Table of Contents

Advertisement

FS-8700-36 Weigh-Tronix

2. FieldServer as a Weigh-Tronix Client

2.1 Hardware Connections

P1
P2
P1
P2
Rx
Tx
Rx Tx

2.1.1 Setting up the Scale

Setting up the scale requires installing and executing Weigh-Tronix Surposer software. This has
to be obtained from Weigh-Tronix and installed per their user manual.
The procedure below is just a summary of the steps required to configure the Scale and any
technical support regarding the scale should be obtained from Weigh-Tronix.
a.
Install Simposer
b.
Start Weigh-Tronix Simposer
c.
Editors/Configure/Serial Ports/end of message = 05
Serial port = 1
Baud = 9600
Parity = none
Data Bits = 8
Handshake = none
Mode = basic control
d.
Connect computer to scale as instructed by Weigh-Tronix
e.
Editors/Program
Enter the following program
sub com1_message
fmtprint (1)
end sub
getcom$(1)
end sub
Close editor
f.
Editors/print formats
FieldServer Technologies 1991 Tarob Court, Milpitas, California 95035 (408) 262-2299 fax: (408) 262-9042
Visit our website: www.fieldserver.com
P3 P4 P5 P6
P7
P8
R1
R2
N1 N2
RS485
10 Base T
RS232
ETHERNET
P3
P4
P5
P6
P7
P8
R1
R2
Net 1
Net 2
Rx
Tx
Rx
Tx
Rx Tx
Rx
Tx
Rx
Tx
Rx Tx
Rx Tx
Rx
Tx
Tx
Rx
Con
Tx Rx Con
DB25M
Customer
Responsibility
E-mail: support@fieldserver.com
Page 2
Driver Manual
Weigh-Tronix
TB6
XMT
1
REC
2
3
RTS
CTS
4
GND
5
+5V
6
7
TXA
8
TXB
RXA
9
RXB
10
FROM DB 25M
TO TB6
(Weigh-tronix)
Pin 2
REC
Pin 3
XMT
Pin 6
GND

Advertisement

Table of Contents
loading

Table of Contents

Save PDF