(Supplement to the FieldServer Instruction Manual)
APPLICABILITY & EFFECTIVITY
Effective for all systems manufactured after January 2009
Driver Manual
FS-8700-133 Genisys
A Sierra Monitor Company
Driver Version:
1.01
Document Revision:
1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Genisys FS-8700-133 and is the answer not in the manual?

Questions and answers

Summary of Contents for FieldServer Genisys FS-8700-133

  • Page 1 Driver Manual (Supplement to the FieldServer Instruction Manual) FS-8700-133 Genisys APPLICABILITY & EFFECTIVITY Effective for all systems manufactured after January 2009 A Sierra Monitor Company Driver Version: 1.01 Document Revision:...
  • Page 2: Table Of Contents

    Appendix A.1. Storage Structure for Data Type Bit and Byte ... 12 APPENDIX B. REFERENCE ... 13 FieldServer Technologies 1991 Tarob Court Milpitas, California 95035 USA Web: www.fieldserver.com Tel: (408) 262 2299 Fax: (408) 262 2269 Toll Free: (888) 509 1970 email: support@fieldserver.com TABLE OF CONTENTS Table of Contents...
  • Page 3: Genisys Description

    Logic Controller (VHLC) supports Genisys protocol. IM-188 VHLC GENISYS SOFTWARE MANUAL 100188-008 AB0.PDF is the basis of the Genisys driver. The FieldServer can be configured as a Client. Limited Server side functionality has been implemented for FieldServer’s quality assurance requirements only.
  • Page 4: Hardware Connections

    Connect to one of the RS-232 Ports on the FieldServer FieldServer FieldServer Technologies 1991 Tarob Court Milpitas, California 95035 USA Web: www.fieldserver.com Tel: (408) 262 2299 Fax: (408) 262 2269 Toll Free: (888) 509 1970 email: support@fieldserver.com VHLC Server RJ45...
  • Page 5: Data Array Parameters

    , Bit DA_DO_01 , Bit FieldServer Technologies 1991 Tarob Court Milpitas, California 95035 USA Web: www.fieldserver.com Tel: (408) 262 2299 Fax: (408) 262 2269 Toll Free: (888) 509 1970 email: support@fieldserver.com Legal Values Up to 15 alphanumeric characters FLOAT, Packed_Bit, Byte, Packed_Byte,...
  • Page 6: Configuring The Fieldserver As A Genisys Client

    This section documents and describes the parameters necessary for configuring the FieldServer to communicate with a Genisys Server. The configuration file tells the FieldServer about its interfaces, and the routing of data required. In order to enable the FieldServer for Genisys communications, the driver independent FieldServer buffers need to be declared in the “Data Arrays”...
  • Page 7: Client Side Node Descriptors

    Genisys_01 , Genisys Genisys_02 , Genisys FieldServer Technologies 1991 Tarob Court Milpitas, California 95035 USA Web: www.fieldserver.com Tel: (408) 262 2299 Fax: (408) 262 2269 Toll Free: (888) 509 1970 email: support@fieldserver.com , Port , Genisys_Check_Controls , Genisys_Intra_Poll_Delay , P1 , ON , 0.01s...
  • Page 8: Client Side Map Descriptors

    Scan_Interval Rate at which data is polled FieldServer Technologies 1991 Tarob Court Milpitas, California 95035 USA Web: www.fieldserver.com Tel: (408) 262 2299 Fax: (408) 262 2269 Toll Free: (888) 509 1970 email: support@fieldserver.com Page 8 of 13 Legal Values Up to 32 alphanumeric characters One of the Data Array names from “Data...
  • Page 9: Map Descriptor Example: Read Indications

    Indication statuses will be stored in this Data Array FieldServer Technologies 1991 Tarob Court Milpitas, California 95035 USA Web: www.fieldserver.com Tel: (408) 262 2299 Fax: (408) 262 2269 Toll Free: (888) 509 1970 email: support@fieldserver.com Page 9 of 13 , Data_Array_Offset...
  • Page 10: Map Descriptor Example: Write Controls

    FieldServer Technologies 1991 Tarob Court Milpitas, California 95035 USA Web: www.fieldserver.com Tel: (408) 262 2299 Fax: (408) 262 2269 Toll Free: (888) 509 1970 email: support@fieldserver.com Page 10 of 13 , Data_Array_Offset , Function...
  • Page 11: Configuring The Fieldserver As A Genisys Server

    CONFIGURING THE FIEL DSERVER AS A GENISYS SERVER The Server side has been implemented only for FieldServer’s quality assurance requirements. FieldServer Technologies 1991 Tarob Court Milpitas, California 95035 USA Web: www.fieldserver.com Tel: (408) 262 2299 Fax: (408) 262 2269 Toll Free: (888) 509 1970 email: support@fieldserver.com...
  • Page 12: Appendix A. Useful Features

    Driver will store a numeric value of 3 in the Data Array. FieldServer Technologies 1991 Tarob Court Milpitas, California 95035 USA Web: www.fieldserver.com Tel: (408) 262 2299 Fax: (408) 262 2269 Toll Free: (888) 509 1970 email: support@fieldserver.com status/control value...
  • Page 13: Appendix B. Reference

    Client. invalid FieldServer Technologies 1991 Tarob Court Milpitas, California 95035 USA Web: www.fieldserver.com Tel: (408) 262 2299 Fax: (408) 262 2269 Toll Free: (888) 509 1970 email: support@fieldserver.com Action without Baud, Check if connection parameter matches the setting at VHLC.