Appendix C.3. Error Messages - FieldServer FS-8700-130 Driver Manual

Fieldserver technologies server computer drive driver manual
Table of Contents

Advertisement

FS-8700-130 Notifier NCA2/NFS-3030 Manual
System Trouble
LOOP CONTINUITY TEST FAIL LOOP 3
LOOP CONTINUITY TEST FAIL LOOP 4
LOOP CONTINUITY TEST FAIL LOOP 5
LOOP CONTINUITY TEST FAIL LOOP 6
LOOP CONTINUITY TEST FAIL LOOP 7
LOOP CONTINUITY TEST FAIL LOOP 8
LOOP CONTINUITY TEST FAIL LOOP 9
LOOP CONTINUITY TEST FAIL LOOP 10
AMP FAIL
AC FAIL
SCB ASSEM. COM. VERIFIED FAILED
8255 PORT CHIP CONTROL WORD CHECK FAILE
NETWORK COMMUNICATION LINK FAIL PORT A
NETWORK COMMUNICATION LINK FAIL PORT B
STYLE 4 SHORT A L1
STYLE 4 SHORT B L1
STYLE 4 SHORT A L2
STYLE 4 SHORT B L2
STYLE 4 SHORT A L3
STYLE 4 SHORT B L3
STYLE 4 SHORT A L4
STYLE 4 SHORT B L4
STYLE 4 SHORT A L5
STYLE 4 SHORT B L5

Appendix C.3. Error Messages

Most error messages are associated with errors in parsing an incoming message from the Notifier panel. The most
likely cause is a mismatch in expected message format. The driver will flag one of the following error messages
and continue. In most cases the message currently being processed by the driver will also be printed so that any
problems can be easily diagnosed.
Two screens 'System Errors' and 'Driver Messages' exist for displaying errors.
The System Error Screen displays the error number and the Driver messages screen displays the error number,
description and the message received from the NCA/NCA2 Panel.
In debug mode the System Error screen will also include Driver messages.
The following Error Messages appear upon the 'System Errors' Screen
%d means numeric number
%s means string
Messages number 1, 3, 4 and 5 will be displayed just once if generated after rebooting or power cycling the
FieldServer.
Error
#1 FYI. Incoming data is
being abandoned on
Port<%d>
Node<%u>
Loop<%d>
Data_Type<%s>
Address<%d>
FieldServer Technologies 1991 Tarob Court Milpitas, California 95035 USA Web: www.fieldserver.com
Tel: (408) 262-2299 Fax: (408) 262-2269 Toll Free: (888) 509-1970 email: support@fieldserver.com
Address
System Trouble
231
WALK TEST - FIRE PROTECTION IS LIMITED
232
REMOTE PROG MODE ACCESSED
233
DIA PROG. CHANGE DET. SERVICE REQUIRED
234
ISIB DATA MESSAGE RECEIVED ERROR
235
ISIB EXECUTIVE ROUTINE RE-ENTERED
236
DIB TO SIB CABLE BAD OR MISSING
237
UPLOAD/DOWNLOAD MESSAGE RECEIVED
238
GLOBAL DATABASE MISMATCH
239
SIB PROG. CHANGE DET. SERVICE REQUIRED
240
HS-NCM SNIFFER MODE ACTIVE
241
EXCEEDED CONNECTION LIMIT
242
NAM CCBE. PROG LOST
243
MEMORY LOSS
244
DVC COMM LOSS
245
A.C. POWER LOSS. BACK UP ACTIVATED
246
BUZZER OFF-LINE
247
PANEL DOOR OPEN
248
OFF NETWORK
249
INSTALL. ERROR
250
OR AUDIO/TELEPHON
251
EXPANDER MODULES
252
MANUAL CONTROL
253
CAT. COMM. FAULT
254
UNKNOWN
Description
The FieldServer got a recognized
message on this particular port, Node,
loop, Address_Type and Address but
did not find a defined Map Descriptor.
Page 20 of 21
Address
485
486
487
488
489
490
491
492
493
494
495
496
497
498
499
500
501
502
503
504
505
506
507
508
Action
To capture this data, add a new Map
Descriptor with the required parameters.