A
To remove a power supply, unplug the power supply and loosen the two knurled
fasteners with a cross-head screw driver as shown in
supply handle and pull firmly to disengage the modular connector. Slide the power
supply out of its bay.
1.
Confirm that the Heartbeat LED is showing the normal 1 blink per second.
This allows the switch to correctly report power supply status.
2.
Confirm that the new power supply is compatible with the switch air flow
direction. The part number label on the power supply indicates the air flow
direction as shown in
3.
With the AC receptacle on the right, slide the power supply into the bay until
it is firmly seated. Secure the knurled fasteners by hand.
4.
Plug the power cord into the AC receptacle. Confirm that air flow is correct.
59096-06 A
Power Supply 1
Figure 6-1 Power Supply Removal
Figure
Air Flow
Label
Figure 6-2 Power Supply Installation
Power Supply Removal and Replacement
Figure
Power Supply 2
Knurled
Fasteners
6-2.
6 – Removal/Replacement
6-1. Grasp the power
AC
Receptacle
6-3