Vlans - Extreme Networks ExtremeWare Enterprise Manager Installation And User Manual

Version 2.0
Table of Contents

Advertisement

E
W
E
M
S
I
XTREME
ARE
NTERPRISE
ANAGER
ERVER
SSUES
Problem: Need to change polling interval, SNMP request time-out, or number of
SNMP request retries.
To change the default values for the SNMP polling interval, the SNMP request time-out,
or the number of SNMP request retries, edit the file
, found in the
extreme.properties
directory. The defaults and value restrictions are as indicated
< install_dir\ extreme>
in the file, as shown. The full properties file is listed in Appendix D.
#Polling interval in seconds to refresh status of each switch
#Default=300, Minimum=5, Maximum=3600 (1 hour)
Snmp.PollInterval=300
# Number of seconds after which an SNMP request should first time out.
# This is followed by an exponential backoff
# Default=2, Minimum=1, Maximum=10 seconds
Snmp.TimeoutPeriod=2
# Number of retries before timing out.
# Default=1, Minimum=0, Maximum=5
Snmp.NumberOfRetries=1
VLAN
S
Problem: Can only access one of the IP addresses on a VLAN configured with IP
multi-netting.
ExtremeWare Enterprise Manager does not currently support IP multi-netting.
Problem: Configuration fails when attempting to configure a VLAN with a modified
protocol definition.
ExtremeWare Enterprise Manager does not have a mechanism to modify protocols.
When a VLAN is configured through ExtremeWare Enterprise Manager to use a
protocol that does not exist on the switch, the protocol is first created on the switch.
However if a protocol with the same name, but a different definition already exists on
the switch, the operation will fail.
E
W
E
M
I
U
G
E-3
XTREME
ARE
NTERPRISE
ANAGER
NSTALLATION AND
SER
UIDE

Advertisement

Table of Contents
loading

This manual is also suitable for:

Extremeware enterprise manager 2.0

Table of Contents