Installer Information; Pre-Installation - Nordyne P3RD-042K User's Manual And Installation

13 seer single package air conditioner
Table of Contents

Advertisement

SECTION
2.
iNSTALLER
iNFORMATiON
GENERAL
Read the following
instructions
completely
before
performing
the installation.
These instructions
are for the use of qualified
personnel
specially
trained and experienced
in the installation
of this type of equipment
and related system components.
Some states
require installation
and service
personnel
to
be licensed. Unqualified
individuals should not
attempt to interpret these instructions
or install
this equipment.
The single packaged air conditioners
are de-
signed for outdoor installation only and can be
readily connected into the high static duct system
of a home. The only connections
needed for
installation are the supply and return ducts, the
line voltage, and thermostat wiring. A complete
air conditioning
system typically consists of:
. Single Package Air Conditioner
. Home Fittings Kit
. Unit Fittings Kit
. Thermostat
The single package air conditioner is completely
assembled, factory wired, and factory run tested.
The units are ready for easy and immediate
installation.
Inspecting
Equipment:
All units are securely
packed at the time of shipment and, upon arrival,
shou Id be carefully inspected for damage. Claims
for damage (apparent or concealed) should be
filed immediately
with the carrier.
INSTALLATION
1.
SELECTTHE
BEST LOCATION FORTHE
AIR CONDITIONING
UNIT
iMPORTANT:
DO NOT PLACE UNiT UNDER
THE HOME.
,
Select a solid, level position, preferably on a
concrete slab, slightly above the grade level,
and parallel to the home.
.
The hot condenser
air must be discharged
up and away from the home, and if possible,
in a direction with the prevailing wind.
Do not place the unit in a confined space.
.
if practical, place the air conditioner where it
and the ducts will be shaded from the after-
noon sun when the heat load is greatest.
Try to select a site for the unit that is as close
as possible to the proposed return grille loca-
tion.
.
Keep in mind that the length of the supply and
return ducts should be kept to a minimum with
no sharp radiused bends.
2.
UNPACKTHE
UNIT
It is recommended
that the unit be unpacked
at the installation
site to minimize damage due
to handEing.
PRE-INSTALLATION
CHECK
Before any installation
is attempted,
the cool-
ing load of the area to be conditioned
must be
calculated and a system of the proper capacity
selected.
It is recommended
that the area to
be conditioned
be completely
insulated
and
vapor sealed.
The installer should comply with all local codes
and regulations
which govern the installation
of this type of equipment.
Local codes and
regulations
take precedence
over any recom-
mendations
contained
in these instructions.
Consult local building codes and the National
Electrical Code (ANSI CI) for special installation
requirements.
CAUTION:
Do not tip the unit on its side.
Oil
may enter the compressor
cylinders
and cause starting
trouble,
if unit has
been set on its side, restore to upright
position
and do not run for several
hours.Then
run unit for a few seconds.
Do this three or four times
with five
minutes
between
runs.
a. Remove the bands from around the unit.
b. Unfold the top and bottom cap flanges.
c. Carefully remove the top cap and tube.
The electrical supply should be checked to de-
termine if adequate power is available. If there
is any question concerning
the power supply,
contact the local power company.