Range Hood Safety - KitchenAid KXW8730YSS0 Installation Instructions And Use & Care Manual

30" 36" and 48" (76.2 cm, 91.4 cm and 121.9 cm) commercial style wall-mount canopy range hood
Table of Contents

Advertisement

Available languages

Available languages

Partsneeded
• Home power supply cable
• 1 -1/2" (12.7 mm) U Llisted orCSA approved strain relief
• 3 ULlisted wireconnectors
• 1wall o rroofcap
• Metal vent s ystem
• Blower motor s ystem - internal orexternal (see "Blower
Motor S ystem" inthe"Accessories"
section.)
Parts supplied
Remove parts from packages. Check that all parts are included.
2 metal grease filters for 30" (76.2 cm) and 36" (91.4 cm)
models
3 metal grease filters for 48" (121.9 cm) models
Range hood canopy with halogen lamps installed.
1 - 10" (25.4 cm) square to 10" (25.4 cm) round duct
transition with damper
Wood support
Grease drip trays
4- 6 x 80 mm mounting screws
4- 3.5 x 9.5 mm screws
6- 4.2 x 19 mm screws
2 - D5.3 x 20 mm washers
2 - 10 x 50 mm wall anchors
T-20 TORX ®t adapter
I A)Q;II[IOI} I;,_,,@ i]!I,,II[ .f"!_ I@I}l'I:,,>
i
IMPORTANT: Observe all governing codes and ordinances.
Have a qualified technician install the range hood. It is the
installer's responsibility
to comply with installation clearances
specified on the model/serial rating plate. The model/serial
rating
plate is located inside the range hood on the rear wall of the
range hood.
Canopy range hood location should be away from strong draft
areas, such as windows, doors and strong heating vents.
Cabinet opening dimensions that are shown must be used. Given
dimensions
provide minimum clearance.
The canopy range hood is factory set for venting through the roof
or through the wall.
All openings in ceiling and wall where canopy range hood will be
installed must be sealed.
For Mobile Home Installations
The installation of this range hood must conform to the
Manufactured
Home Construction
Safety Standards, Title 24
CFR, Part 328 (formerly the Federal Standard for Mobile Home
Construction
and Safety, Title 24, HUD, Part 280) or when such
standard is not applicable, the standard for Manufactured
Home
Installation 1982 (Manufactured
Home Sites, Communities
and
Setups) ANSI A225.1/NFPA 501A*, or latest edition, or with local
codes.
Product Dimensions
Front view
181/16" ( 45.9 cm) for 48" (121.9 cm) Hood
121/16" ( 30.6 cm) for 36" (91.4 cm) Hood
91/16" ( 23.0 cm) for 30" (76.2 cm) Hood
CL
(16.5cm)
12" (30.5cm)
33/16 ''
(8.1
Back view
I
i
i
I
B
//
18"
(45.7 cm)
121¾o"(32.5 crn) for 36" (91.4 cm) Hood
91¾o" (24.9 cm) for 30" (76.2 cm) Hood
A. Knockout
into terminal box
B. Top of hood
C. Wood support
D. Bottom of hood
Optional Full-Width Duct Cover Installations
12"
(._.5
crn)
12"
18"
A. Qptional full-width
duct cover
B. Range hood
B
1-®TORX is a registered trademark
of Saturn Fasteners, Inc.

Advertisement

Table of Contents
loading

This manual is also suitable for:

Kxw8736yss0Kxw8748yss0

Table of Contents