6.
7,
Connect the same color wires to each other (black to black,
white to white, etc.) using UL listed wire connectors.
NOTE: Connect the green (or green/yellow)
ground wire from
the wiring conduit to the green (or bare) ground wire from the
home power supply using UL listed wire connectors
(see the
"Make Electrical Power Supply Connections
to Range Hood"
section).
B
C
D
E
A
A. UL listed or CSA approved
½" (1.3 cm) wiring conduit
B. UL listed wire connectors
C. Black wires
D. White wires
F
G
H
E. Red wires
F. Blue wires
G. Gray wires
H. Green (or green/yellow) wire
I. 6-wire connector assembly
Go to "Make Electrical Power Supply Connection
to Range
Hood" section.
Electrical Shock Hazard
Disconnect power before servicing.
Replace all parts and panels before operating.
Failure to do so can result in death or electrical
shock.
1. Disconnect
power.
2. Locate terminal box inside of the range hood.
E
C
A. White wires
B. Black wires
C. UL listed wire connectors
D. Green, bare or yellow/green
wires
E. Home power supply
F. UL listed or CSA approved
½" (1.3 cm) strain refief
3. Use UL listed wire connectors
and connect black wires (B)
together.
4. Use UL listed wire connectors
and connect white wires (A)
together.
Electrical Shock Hazard
Electrically ground blower.
Connect ground
wire to green and yellow ground wire
in terminal
box.
Failure to do so can result in death or electrical
shock.
NOTE: When using an in-line blower motor system, the green (or
green/yellow)
ground wire in the conduit from the In-line blower
motor system is to be connected with the green (or bare) wire of
the home power supply cable and with the green/yellow wire (D)
in the terminal box.
5. Connect green (or bare) ground wire from home power supply
to the green/yellow ground wire (D) in terminal box using UL
listed wire connectors.
6. Install terminal box cover.
7. Check that all light bulbs are secure in their sockets.
8. Reconnect power.
B
A. Terminal box cover
B. Knockout
in canopy back into terminal box