KitchenAid KBNU367T Manual page 14

Freestanding and built-in outdoor grills
Table of Contents

Advertisement

Available languages

Available languages

4.
Screw the gas pressure regulator/hose
assembly to the 20 Ib
LP gas fuel tank as shown.
Pipe-joint compounds
suitable for use with Natural gas
must be used. Do not use TEFLON ®t tape.
A
...............................................
g
C
............................................................
A. 20 Ib LP gas fuel tank
B. Gas pressure regulator/hose
assembly
5. Turn on the gas supply. Wait a few minutes for gas to move
through the gas line.
6. Test all connections
by brushing on an approved
noncorrosive
leak-detection
solution. Bubbles will show a
leak. Correct any leak found.
7. Go to "Check and Adjust the Burners" section.
If Converted to Natural Gas
Explosion Hazard
Use a new CSA International
approved
"outdoor"
gas supply line.
Securely tighten
all gas connections.
Failure to do so can result in death, explosion,
or fire.
This installation must conform with local codes and ordinances.
In the absence of local codes, installations must conform with
either the National Fuel Gas Code ANSI Z223.1, or CAN/CGA-
B149.1 Natural Gas and Propane installation code.
Copies of the standards listed above may be obtained from:
CSA International
8501 East Pleasant Valley Rd.
Cleveland, Ohio 44131-5575
National Fire Protection Association
One Batterymarch
Park
Quincy, Massachusetts
02269
1. Make gas connections.
A combination
of pipe fittings must be used to connect the
grill to the existing gas line.
If local codes permit, use an outdoor flexible stainless
steel tubing gas connector, design-certified
by CSA
International,
to connect the grill to the rigid gas supply
line. A %" diameter line is recommended.
Using a wrench
to tighten, connect the gas supply to the grill. Use pipe-
joint compound
on all non-flared male threads. Do not
kink or damage the flexible connector when moving the
grill.
2.
A. Grill gas pipe
B. New ANSI Z21.54 certified gray hose
C. Rear of grifl
D. To Natural gas supply
Open the manual shutoff valve in the gas supply line. The
valve is open when the handle is parallel to the gas pipe.
A. Closed valve
B. Open valve
3. Test all connections
by brushing on an approved
noncorrosive
leak-detection
solution. Bubbles will show a
leak. Correct any leak found.
4. Go to "Check and Adjust the Burners" section.
Plug in Grill
Electrical Shock Hazard
Plug into a grounded
3 prong outlet.
Do not remove ground
prong.
Do not use an adapter.
Do not use an extension
cord.
Failure to follow these instructions can result in death,
fire, or electrical
shock.
1. Plug into a grounded 3-prong outlet.
1-®TEFLON is a registered trademark
of E.I. Du Pont De Nemours and Company.
14

Advertisement

Table of Contents
loading

This manual is also suitable for:

Kfru368tKbnu487tKfru488t

Table of Contents