INSTALLATION REQUIREMENTS
Gather the required tools and parts before starting installation.
Read and follow the instructions
provided with any tools listed
here.
Tools Needed
Jigsaw or keyhole saw
Drill
3/le" (5 mm) drill bit for 3ilot holes
Pencil
Tape measure or ruler
1/8"Flat-blade screwdriver
Phillips screwdriver
1/2H and %d' Open-end wrenches or adjustable wrench
11¼"(32 mm) drill bit
Level
Metal snips
Wire stripper or utility knife
Caulking gun and weatherproof
caulking compound
Parts Supplied
Remote control with batteries
2 - Grease filters
Top frame
Frame support
12 - 4 x 10 mm flat-head screws
10" (25.4 cm) diameter vent collar
Vent collar mounting frame (attached)
Remote up/down switch
4 - Cable tie mounting bases
4- Cable ties
Curved glass panel
4 - Leveler feet with nuts
2 - Undercounter
mounting brackets
8- 5 mm x 12 mm pan-head screws
6- 4 x 20 mm wood screws
Parts Needed
UL listed or CSA approved 1/2"(12.7 mm) conduit connector
Wall or roof cap with damper to match vent system
Vent system
Wiring cable for remote blower kit
Vent clamps/duct
tape
Blower motor system (see the "Accessories"
section for
information
on ordering)
NOTE: Downdraft vent is installed directly behind the cooktop.
For ease of installation, install the downdraft vent system first,
then install the cooktop.
IMPORTANT: Observe all governing codes and ordinances.
Have a qualified technician install the downdraft vent. It is the
installer's responsibility to comply with installation clearances
specified on the model/serial rating plate. The model/serial
rating plate is located on the front of the downdraft vent.
Downdraft vent location should be away from strong draft
areas, such as windows, doors, and strong heating vents or
fans.
Cabinet opening dimensions that are shown must be used.
Given dimensions provide minimum clearance.
Consult the cooktop manufacturer
Installation Instructions
before making any cutouts.
Check that the downdraft vent and cooktop location will
clear the cabinet walls, backsplash, and rear wall studs
inside the cabinet.
Check for the minimum distance between the front edge
of the countertop and the front edge of the cooktop. The
minimum horizontal distance between the overhead
cabinets is the same as the width of the installed
downdraft vent.
All openings in ceiling and wall where the downdraft vent will
be installed must be sealed.
Grounded electrical outlet is required. See "Electrical
Requirements"
section.
For Mobile Home Installations
The installation of this downdraft vent must conform to the
Manufactured
Home Construction
Safety Standards, Title 24
CFR, Part 328 (formerly the Federal Standard for Mobile Home
Construction
and Safety, title 24, HUD, Part 280) or when such
standard is not applicable, the standard for Manufactured
Home
Installation 1982 (Manufactured
Home Sites, Communities and
Setups) ANSI A225.1/NFPA 501A, or latest edition, or with local
codes.