Install Downdraft Vent In-Line (External Type) Blower Motor - Jenn-Air JXD7836BS0 Use & Care Manual

36" (91.4 cm) contour ventilation system
Table of Contents

Advertisement

Available languages

Available languages

6. Center andlevel the topofthedowndraft vent l efttoright a nd
front t oback. U se aWle" wrench t olockthefeetintoposition
withtheIocknuts.
7. Secure thehood vent b oxtothecountertop orcabinet sides
withtheundercounter
mounting brackets attached earlier at
thedesired l ocation. If mounting toa countertop, usescrews
ormounting method r ecommended
forthespecific t ype of
countertop.
8. Install thetopframe s upport, using the12-3.9x9 mm
flat-head screws.
9. Install thetopframe.
B
E
A. 12 Flat-head screws
B. Top frame
C. Guide pins in top frame
D. Hole for top frame guide pins
E. Top frame support
Prepare for Mounting
the In-Line Blower System
The in-line blower system must be fastened to a secure structure
of the roof, ceiling, wall, floor, or new or existing frame
construction.
The 4 holes on either the inlet (bottom) side or the
outlet (top) side of the blower must be used to mount the in-line
blower system to the structure.
NOTE: The mounting hole locations must span the studs.
Additional stud framing may be required. Plywood may be used
to span open areas between ceiling or floor joists or roof rafters
to aid installation. This structure must be strong enough to
support the weight of the in-line blower system (50 Ib
[22.7 kg] min).
Prepare the In-line Blower System
Excessive Weight Hazard
Use two or more people to move and install in-line
blower motor system.
Failure to do so can result in back or other injury.
1. Using 2 or more people, move the in-line blower motor
system to the mounting location.
2. Remove the 10 screws from the front cover of the in-line
blower motor housing and set them aside.
3. Remove the front cover of the in-line blower motor housing
and set it aside.
NOTE: To make the blower motor housing easier to mount,
the blower motor assembly can be removed. If you do not
want to remove the blower motor assembly, proceed to
"Install In-line Blower System" in this section.
4. Disconnect
the motor electrical plug from the blower motor
assembly.
5. Remove the screws that secure the blower motor assembly
to the in-line blower housing and set them aside.
6. Pull the spring clip to release the blower motor assembly.
Remove the blower motor assembly from the housing and
place it on a covered surface.
A
C
D
A. Front cover
B. Blower mounting screws
C. Spring clip
D. Motor electrical plug
10

Advertisement

Table of Contents
loading

Table of Contents