Installation Requirements; Tools And Parts; Location Requirements - Jenn-Air JXI8736DS Installation Instructions And Use & Care Manual

36 91.4 cm wall-mount canopy range hood
Table of Contents

Advertisement

Available languages

Available languages

Tools and Parts

Gather the required tools and parts before starting installation.
Read and follow the instructions provided with any tools
listed here.
Tools needed:
Level
Drill with 1
/
" (3.0 cm) and
1
4
Pencil
Wire stripper or utility knife
Tape measure or ruler
Pliers
Caulking gun and weatherproof caulking compound
Vent clamps
Jigsaw or keyhole saw
Flat-blade screwdriver
Metal snips
Phillips screwdriver
TORX
T20
bit or driver
®†
®†
Parts needed:
For hard wire installations, you will also need:
Home power supply cable
/
" (12.7 mm) UL listed or CSA approved strain relief
1
2
For vented installations, you will also need:
1 wall or roof cap
Metal vent system
For non-vented (recirculating) installations, you will
also need:
Chimney Kit Recirculation for non-vented (recirculating)
installations only. See the "Assistance or Service" section
to order.
Charcoal Filter Kit Part Number W10272069.
See "Assistance or Service" section to order.
Parts supplied:
Remove parts from packages. Check that all parts are included.
Hood canopy assembly with ventilator and lights installed
Vent mounting boss (attached to hood canopy assembly)
Damper
3 - 3.5 x 9.5 mm screws damper to mounting boss
Metal grease filter installed in hood canopy
Chimney cover support bracket
2-piece chimney cover
2 - 8 x 80 mm hanger bolts (T20
2 - 8 mm nuts
2 - flat washers
2 - 5 x 40 mm Torx
®
T20
bracket mounting.
2 - 5 mm wall anchors
1
/
" (13 mm) special nut tightening tool
2
2 - plastic spacers for lower chimney
TORX and †®T20 are registered trademarks of Acument Intellectual Properties, LLC.

INSTALLATION REQUIREMENTS

/
" (5.0 mm) drill bits
3
16
TORX
drive)
®
®
®
drive screws for chimney

Location Requirements

IMPORTANT: Observe all governing codes and ordinances.
Have a qualified technician install the range hood. It is the
installer's responsibility to comply with installation clearances
specified on the model/serial/rating plate. The model/serial/
rating plate is located behind the left filter on the rear wall of
the vent hood.
Canopy hood location should be away from strong draft
areas, such as windows, doors, and strong heating vents.
Cabinet opening dimensions that are shown must be used.
Given dimensions provide minimum clearance.
The canopy hood mounting location must be capable
of supporting 100 lbs (45.4 kg).
This range hood is recommended for use with cooktops
with a maximum total rating of 78,000 Btus or less.
Grounded electrical outlet is required. See the "Electrical
Requirements" section.
For non-vented (recirculating) Installation see "Non-vented
(recirculating) Installations" in the "Install Range Hood" section.
Chimney Kit Recirculation and Charcoal Filter Kit Part Number
W10272069 are available from your dealer or an authorized parts
distributor. See the "Assistance or Service" section to order.
All openings in ceiling and wall where canopy hood will be
installed must be sealed.
For Mobile Home Installations:
The installation of this range hood must conform to the
Manufactured Home Construction Safety Standards, Title 24
CFR, Part 328 (formerly the Federal Standard for Mobile Home
Construction and Safety, Title 24, HUD, Part 280) or when such
standard is not applicable, the standard for Manufactured Home
Installation 1982 (Manufactured Home Sites, Communities
and Setups) ANSI A225.1/NFPA 501A or latest edition, or
with local codes.
Product Dimensions
A
B
C
A. 12
/
" (31.4 cm)
3
8
B. 13
/
" (33.4 cm)
1
8
C. 36" (91.4 cm)
D. 21
/
" (54.8 cm)
9
16
G
F
E
D
E. 1
/
" (4.2 cm)
5
8
F. 25
/
" (65.0 cm)
9
16
G. 33
/
" (84.1 cm) min.
1
8
54
/
" (139.1 cm) max.
3
4
5

Advertisement