Jenn-Air W10201609B Installation Instructions And Use And Care Manual

30" and 36" (76.2 cm and 91.4 cm) retractable (pop-up) downdraft vent system
Table of Contents

Advertisement

Available languages

Available languages

Quick Links

JENN-AIR
®
30" AND 36" (76.2 CM AND 91.4 CM)
RETRACTABLE (POP-UP) DOWNDRAFT VENT SYSTEM
SYSTÈME D'EXTRACTION RÉTRACTABLE (CLAPET) À
®
ASPIRATION PAR LE BAS JENN-AIR
DE
30" ET 36" (76,2 CM ET 91,4 CM)
Installation Instructions and Use & Care Guide
For questions about features, operation/performance, parts, accessories, or service in the U.S.A., call:
1-800-JennAir (1-800-536-6247) or visit our website at www.jennair.com.
In Canada, call: 1-800-807-6777, or visit our website at www.jennair.ca.
Instructions d'installation et Guide d'utilisation et d'entretien
Au Canada, pour assistance, installation ou service, composez le 1-800-807-6777 ou visitez notre site web à www.jennair.ca.
Table of Contents/Table des matières...............2
IMPORTANT: READ AND SAVE THESE INSTRUCTIONS.
FOR RESIDENTIAL USE ONLY.
IMPORTANT : LIRE ET CONSERVER CES INSTRUCTIONS.
POUR UTILISATION RÉSIDENTIELLE UNIQUEMENT.
W10201609D

Advertisement

Table of Contents
loading

Summary of Contents for Jenn-Air W10201609B

  • Page 1 RETRACTABLE (POP-UP) DOWNDRAFT VENT SYSTEM SYSTÈME D’EXTRACTION RÉTRACTABLE (CLAPET) À ® ASPIRATION PAR LE BAS JENN-AIR 30" ET 36" (76,2 CM ET 91,4 CM) Installation Instructions and Use & Care Guide For questions about features, operation/performance, parts, accessories, or service in the U.S.A., call: 1-800-JennAir (1-800-536-6247) or visit our website at www.jennair.com.
  • Page 2: Table Of Contents

    TABLE OF CONTENTS VENT SYSTEM SAFETY...3 INSTALLATION REQUIREMENTS ...5 Tools and Parts ...5 Location Requirements ...5 Electrical Requirements ...7 Venting Requirements...7 INSTALLATION INSTRUCTIONS INTERIOR-MOUNTED VENT MOTOR...8 Venting Methods - Interior Mounted Vent Motor Only ...8 Install Vent System...9 Rear Mounting - Blower Motor ...13 Complete Installation ...15 Make Electrical Connections ...15 Check Operation ...16...
  • Page 3: Vent System Safety

    Your safety and the safety of others are very important. We have provided many important safety messages in this manual and on your appliance. Always read and obey all safety messages. This is the safety alert symbol. This symbol alerts you to potential hazards that can kill or hurt you and others. All safety messages will follow the safety alert symbol and either the word “DANGER”...
  • Page 4: Important Safety Instructions

    IMPORTANT SAFETY INSTRUCTIONS WARNING: TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING: Use this unit only in the manner intended by the manufacturer. If you have questions, contact the manufacturer. Before servicing or cleaning the unit, switch power off at service panel and lock the service disconnecting means to prevent power from being switched on accidentally.
  • Page 5: Installation Requirements

    INSTALLATION REQUIREMENTS Tools and Parts Gather the required tools and parts before starting installation. Read and follow the instructions provided with any tools listed here. Tools Needed Jigsaw or keyhole saw Drill " (3 mm) drill bit for pilot holes Pencil Tape measure or ruler Flat-blade screwdriver...
  • Page 6 Product Dimensions Interior-mounted blower motor model Top trim widths: 30 " (76.8 cm) for 30" (76.2 cm) vent 36 " (92.1 cm) for 36" (91.4 cm) vent " (34.3 cm) retractable vent height 27" (68.6 cm) for 30" (76.2 cm) vent 33"...
  • Page 7: Electrical Requirements

    IMPORTANT: Observe all governing codes and ordinances. Save Installation Instructions for electrical inspector’s use. It is the customer’s responsibility to contact a qualified electrical installer, and to ensure that the electrical installation is adequate and in conformance with National Electrical Code, ANSI/NFPA 70 (latest edition), or CSA Standards C22.1-94, Canadian Electrical Code, Part 1 and C22.2 No.
  • Page 8: Installation Instructions Interior-Mounted Vent Motor

    INSTALLATION INSTRUCTIONS INTERIOR-MOUNTED VENT MOTOR Venting Methods - Interior Mounted Vent Motor Only Determine which venting method is best for your application. Vent system can terminate through either the wall or floor. Island location Front (standard) mounted Rear mounted blower blower motor A.
  • Page 9: Install Vent System

    To calculate the length of the system you need, add the equivalent feet (meters) for each vent piece used in the system. Vent Piece 6" (15.2 cm) Round 45° elbow 2.5 ft (0.8 m) 90° elbow 5.0 ft (1.5 m) 6"...
  • Page 10 5. Attach the left and right side end caps to the downdraft vent. Place the end cap upon the overcounter support, slide the tab into the slot and snap into place over the the plastic tabs. A. End cap 6. Attach support legs to the side of the downdraft vent with 2 screws in each leg.
  • Page 11 4. Place the bottom tab of the blower box into the bottom mounting channel. A. Blower box B. Bottom mounting channel 5. Tilt blower box top tab so it is flush with the vent box panel and position it under the top mounting bracket. Slide bracket into the “Z”...
  • Page 12 6. Install blower motor and mounting bracket assembly to the bracket just below the downdraft tower motor. The blower exhaust opening should fit through the hole in the large cover plate on the opposite side of the vent chamber where the small cover plate was removed.
  • Page 13: Rear Mounting - Blower Motor

    NOTE: Optional blower motor mounting position (opposite side). The blower motor box assembly can also be moved to the opposite side (rear) of the vent box. A. Panel B. Blower motor - rear mounting 1. Loosen the 2 hex/slotted head screws that attach the top bracket that secures the motor to the vent box enough to slide the bracket into the “Z”...
  • Page 14 5. Lift up the panel from the bottom mounting channel. A. Blower mounting channel B. Panel 6. Install the blower motor box assembly to the opposite side (rear) of the vent box with the vent located in the bottom venting position. Place the bottom tab of the blower box into the bottom mounting channel.
  • Page 15: Complete Installation

    Complete Installation 1. Attach backdraft damper over 6" vent extension. Secure with vent clamp. A. 6" vent extension B. Backdraft damper 2. Remove screw attaching the terminal box cover. A. Terminal box cover Determine which direction (rear or bottom) electrical connection will need to run from vent system terminal box.
  • Page 16: Check Operation

    4. Connect the 2 white wires together using UL listed wire connectors. A. Green or green and yellow ground wire B. Green ground screw C. White wires D. UL listed wire connectors E. Black wires F. UL listed or CSA approved conduit connector G.
  • Page 17: Vent System Use

    The retractable downdraft vent system is designed to remove smoke, cooking vapors and odors from the cooktop area. For best results, the vent should be operating before cooking is started. If you use large or tall utensils, place them on the large rear element or burner surface.
  • Page 18: Wiring Diagram

    GEAR MOTOR FILTER SWITCHES TOROIDAL TRANSFORMER LINE IN 120 Vac 60 Hz WIRING DIAGRAM 5x20 800 mA Time Delay FUSE VDR1 SIDE INSERT CABLES PUSH BUTTON REGULATION UP/DOWN FLAT CABLE ELDD INTERNAL BLOWER SPEED...
  • Page 19: Assistance Or Service

    “Troubleshooting” section… Call the dealer from whom your appliance was purchased, or call Jenn-Air at 1-800-688-1100 to locate an authorized service company. When calling, please know the purchase date and the complete model and serial number of your appliance. Be sure to retain proof of purchase to verify warranty status.
  • Page 20: Warranty

    Jenn-Air brand of Whirlpool Corporation or Whirlpool Canada LP (hereafter “Jenn-Air”) will pay for factory specified parts and repair labor to correct defects in materials or workmanship. Service must be provided by a Jenn-Air designated service company. This limited warranty is valid only in the United States or Canada and applies only when the major appliance is used in the country in which it was purchased.
  • Page 21 Notes...
  • Page 22: Sécurité Du Système De Ventilation

    SÉCURITÉ DU SYSTÈME D'EXTRACTION Votre sécurité et celle des autres est très importante. Nous donnons de nombreux messages de sécurité importants dans ce manuel et sur votre appareil ménager. Assurez-vous de toujours lire tous les messages de sécurité et de vous y conformer. Voici le symbole d’alerte de sécurité.
  • Page 23 IMPORTANTES INSTRUCTIONS DE SÉCURITÉ AVERTISSEMENT : POUR RÉDUIRE LE RISQUE D'INCENDIE, CHOC ÉLECTRIQUE OU DOMMAGES CORPORELS, RESPECTER LES INSTRUCTIONS SUIVANTES : Utiliser cet appareil uniquement dans les applications envisagées par le fabricant. Pour toute question, contacter le fabricant. Avant d'entreprendre un travail d'entretien ou de nettoyage, interrompre l'alimentation de la hotte au niveau du tableau de disjoncteurs, et verrouiller le tableau de disjoncteurs pour empêcher tout rétablissement accidentel de...
  • Page 24: Exigences D'installation

    EXIGENCES D'INSTALLATION Outillage et pièces Rassembler les outils et pièces nécessaires avant de commencer l'installation. Lire et observer les instructions fournies avec les outils de cette liste. Outillage nécessaire Scie sauteuse ou scie à guichet Perceuse Foret de " (3 mm) pour avant-trous Crayon Mètre-ruban ou règle Tournevis à...
  • Page 25 Dimensions du produit Modèle avec ventilateur monté à l'intérieur Système d'extraction rétractable - hauteur de 13 " (34,3 cm) 27" (68,6 cm) pour système d'extraction de 30" (76,2 cm) 33" (83,8 cm) pour système d'extraction de 36" (91,4 cm) Couvercle du boîtier de connexion 13"...
  • Page 26: Spécifications Électriques

    IMPORTANT : Observer les dispositions de tous les codes et règlements en vigueur. Conserver les instructions d'installation pour consultation par l'inspecteur des installations électriques. C'est au client qu'incombe la responsabilité de contacter un électricien qualifié et de veiller à ce que l'installation électrique soit adéquate et réalisée en conformité...
  • Page 27: Instructions D'installation Ventilateur Monté À L'intérieur

    INSTRUCTIONS D'INSTALLATION VENTILATEUR MONTÉ À L'INTÉRIEUR Méthodes d'extraction - Seulement pour un ventilateur monté à l'intérieur Déterminer quelle méthode d’extraction est la plus appropriée. La sortie à l'extérieur du système d’extraction peut se faire à travers le plancher ou à travers un mur. Configuration de cuisine en îlot Ventilateur monté...
  • Page 28: Installation Du Système D'extraction

    Pour calculer la longueur effective du système d’extraction nécessaire, additionner les longueurs équivalentes (pieds/mètres) de tous les composants utilisés dans le système. Composant Système de diamètre 6" (15,2 cm) Coude à 45° 2,5 pi (0,8 m) Coude à 90° 5 pi (1,5 m) Bouche de décharge 0 pi...
  • Page 29 6. Fixer les pieds de support sur les côtés de l'appareil - 2 vis pour chaque pied. Ne pas serrer les vis. A. Boîte du moteur de ventilateur B. Pied de support 7. Faire intervenir 2 personnes ou plus, insérer le système d’extraction par le bas dans l'ouverture découpée dans l'ouverture du plan de travail.
  • Page 30 5. Incliner la patte supérieure de la boîte du ventilateur pour la placer en affleurement avec le panneau de la boîte du système d’extraction et la positionner sous la bride de montage supérieure. Faire glisser la bride dans les rainures en “Z”...
  • Page 31 7. Brancher le connecteur du câblage sur le moteur du ventilateur. A. Moteur du ventilateur B. Connecteur du câblage 8. Placer le raccord d'extension de diamètre 6" sur l’orifice de décharge; fixer avec les 4 vis. A. Vis (4) (raccord d'extension) 9.
  • Page 32: Montage Du Ventilateur À L'arrière

    REMARQUE : Position de montage du ventilateur facultative (côté opposé). On peut également déplacer la boîte du moteur du ventilateur du côté opposé (arrière) de la boîte du système d'extraction. A. Panneau B. Moteur du ventilateur - montage arrière 1. Desserrer les 2 vis (tête hex/fente droite) fixant la bride supérieure de montage du moteur sur la boîte du système d’extraction, suffisamment pour pouvoir faire glisser la bride dans les rainures en “Z”;...
  • Page 33 5. Dégager le panneau du profilé de montage inférieur en le soulevant. A. Profilé de montage du ventilateur B. Panneau 6. Installer la boîte du moteur du ventilateur du côté opposé (arrière) de la boîte du système d’extraction avec le conduit d'évacuation placé...
  • Page 34: Achever L'installation

    Achever l'installation 1. Connecter le clapet anti-reflux au raccord d’extension de 6". Le fixer avec la bride de conduit. A. Raccord d'extension - diam. 6" B. Clapet anti-reflux 2. Ôter la vis fixant le couvercle du boîtier de connexion. A. Couvercle du boîtier de connexion Déterminer l'orientation de sortie (par l’arrière ou le fond) du câblage électrique depuis le boîtier de connexion de l'appareil.
  • Page 35: Contrôle Du Fonctionnement

    4. Connecter ensemble les deux connecteurs blancs avec un connecteur de fils (homologation UL). A. Conducteur de liaison à la terre (vert or vert/jaune) B. Vis de liaison à la terre (verte) C. Conducteurs blancs D. Connecteurs de fils (homologation UL) E.
  • Page 36: Utilisation Du Système D'extraction

    UTILISATION DU SYSTÈME D'EXTRACTION La fonction du système d’extraction par le bas est d'aspirer et évacuer hors de la cuisine les vapeurs et fumées de cuisson, sources d'odeurs. Pour optimiser la performance, on devrait faire fonctionner le système d'extraction avant d'entreprendre une cuisson. Lors de l'emploi d'un ustensile de grande taille, placer celui-ci sur un brûleur ou élément chauffant de grande taille, à...
  • Page 37: Schéma De Câblage

    SCHÉMA DE CÂBLAGE MOTEUR (ENGRENAGES) COMMUTATEURS (FILTRE) GRIS GRIS TRANSFORMATEUR TOROÏDAL VDR1 CONNEXION 120 V CA, 60 Hz Fusible temporisé, 5x20 800 mA FUSIBLE (connecteur) (connecteurs) L1 (phase) ELDD INSERTION DES CÂBLES (CÔTÉ) VENTILATEUR RÉGULATEUR BOUTON POUSSOIR DE VITESSE HAUT/BAS CÂBLE PLAT GRIS GRIS...
  • Page 38: Assistance Ou Service

    “Dépannage”… Téléphonez au marchand qui vous a vendu l'appareil ou téléphonez à Jenn-Air au 1-800-688-1100 pour localiser une compagnie de service autorisée. Lors d'un appel, veuillez connaître la date d'achat et les numéros de modèle et de série complets de votre appareil.
  • Page 39: Garantie

    5. Les défauts apparents, notamment les éraflures, les bosses, fissures ou tout autre dommage au fini du gros appareil ménager, à moins que ces dommages soient dus à des vices de matériaux ou de fabrication et soient signalés à Jenn-Air dans les 30 jours suivant la date d’achat.
  • Page 40 ® Registered Trademark/™ Trademark of Jenn-Air U.S.A. © 2009 Used under license by Maytag Limited in Canada. 9/09 All rights reserved. ® Marque déposée/™ Marque de commerce de Jenn-Air U.S.A. Printed in Italy Tous droits réservés. Emploi sous licence au Canada. Imprimé en Italie...

This manual is also suitable for:

Jxdr7301vs

Table of Contents