Jenn-Air JXD7036YS Installation Instructions And Use & Care Manual

Jenn-Air JXD7036YS Installation Instructions And Use & Care Manual

30" (76.2 cm) and 36" (91.4 cm) retractable (pop-up) downdraft vent system
Hide thumbs Also See for JXD7036YS:
Table of Contents

Advertisement

Available languages

Available languages

30" (76.2 CM) AND 36" (91.4 CM)
RETRACTABLE (POP-UP) DOWNDRAFT VENT
SYSTEM
SYSTÈME DE VENTILATION RÉTRACTABLE
(CLAPET) DE 30" (76,2 CM) ET 36" (91,4 CM) -
ASPIRATION PAR LE BAS
Installation Instructions and Use & Care Guide
For questions about features, operation/performance, parts, accessories, or service in the U.S.A., call:
1-800-JENNAIR (1-800-536-6247), or visit our website at www.jennair.com.
In Canada, call: 1-800-JENNAIR (1-800-536-6247), or visit our website at www.jennair.ca.
Instructions d'installation et Guide d'utilisation et d'entretien
Au Canada, pour assistance, installation ou service, composez le 1-800-JENNAIR (1-800-536-6247) ou visitez notre site web à
www.jennair.ca.
Table of Contents/Table des matières ................................. 2
IMPORTANT: READ AND SAVE THESE INSTRUCTIONS.
FOR RESIDENTIAL USE ONLY.
IMPORTANT : LIRE ET CONSERVER CES INSTRUCTIONS.
POUR UTILISATION RÉSIDENTIELLE UNIQUEMENT.
LI3ZVC/W10342490E

Advertisement

Table of Contents
loading

Summary of Contents for Jenn-Air JXD7036YS

  • Page 1 30" (76.2 CM) AND 36" (91.4 CM) RETRACTABLE (POP-UP) DOWNDRAFT VENT SYSTEM SYSTÈME DE VENTILATION RÉTRACTABLE (CLAPET) DE 30" (76,2 CM) ET 36" (91,4 CM) - ASPIRATION PAR LE BAS Installation Instructions and Use & Care Guide For questions about features, operation/performance, parts, accessories, or service in the U.S.A., call: 1-800-JENNAIR (1-800-536-6247), or visit our website at www.jennair.com.
  • Page 2: Table Of Contents

    TABLE OF CONTENTS TABLE DES MATIÈRES VENT SYSTEM SAFETY..............3 SÉCURITÉ DU SYSTÈME DE VENTILATION......19 INSTALLATION REQUIREMENTS ..........5 EXIGENCES D'INSTALLATION ...........21 Tools and Parts ................5 Outils et pièces................21 Location Requirements..............5 Exigences d’emplacement............21 Electrical Requirements ...............8 Spécifications électriques ............24 Venting Requirements..............8 Exigences concernant l'évacuation ...........24 INSTALLATION INSTRUCTIONS ..........9 INSTRUCTIONS D'INSTALLATION..........25 Venting Methods ................9...
  • Page 3: Vent System Safety

    VENT SYSTEM SAFETY Your safety and the safety of others are very important. We have provided many important safety messages in this manual and on your appliance. Always read and obey all safety messages. This is the safety alert symbol. This symbol alerts you to potential hazards that can kill or hurt you and others.
  • Page 4 IMPORTANT SAFETY INSTRUCTIONS READ AND SAVE THESE INSTRUCTIONS...
  • Page 5: Installation Requirements

    INSTALLATION REQUIREMENTS Tools and Parts Location Requirements Gather the required tools and parts before starting installation. NOTE: Downdraft vent is installed directly behind the cooktop. Install the downdraft vent first, then install the cooktop. Read and follow the instructions provided with any tools listed here.
  • Page 6: Product Dimensions

    Product Dimensions Top trim widths: 30" (76.2 cm) 36" (91.4 cm) 13¹⁄₂" (34.3 cm) retractable vent height 1¹⁄₂" (3.8 cm) ³⁄₈" (0.95 cm) 27" (68.6 cm) for 30" (76.2 cm) vent 33" (83.8 cm) for 36" (91.4 cm) vent 5¹⁄₄"(13.3 cm) for 30"...
  • Page 7 Cabinet Dimension 10" (25.4 cm) A= ¹⁄₂" (12.7 mm) minimum 21⁵⁄₁₆" (54.1 cm) 21⁵⁄₁₆" (54.1 cm) Cutouts are for 3¹⁄₄" x 10" (8.3 x 25.4 cm) rectangular or 6" (15.2 cm) round vent system. Centerline of cooktop cutout Locate power supply junction box at lower left hand...
  • Page 8: Electrical Requirements

    Countertop Cutout Dimensions Chart Venting Requirements IMPORTANT: Make sure there is proper clearance within the wall or floor before making exhaust vent cutouts. ■ Use heavy (rigid) metal vent. ■ Venting system must terminate to the outside. ■ Do not terminate the vent system in an attic or other enclosed area.
  • Page 9: Installation Instructions

    INSTALLATION INSTRUCTIONS Venting Methods Determine which venting method is best for your application. Island Location - Vent System Installed Under a Vent system can terminate either through the wall or floor. Concrete Slab Using PVC Sewer Pipe Island Location Front (Standard) Mounted Blower Motor Front (Standard)-Mounted Rear-Mounted Blower Blower Motor...
  • Page 10: Install Vent System

    To calculate the length of the system you need, add the Example Vent System equivalent feet (meters) for each vent piece used in the system. 3¹⁄₄" x 10" (8.3 cm x 25.4 cm) 6 ft Vent Piece Rectangular (1.8 m) 3¹⁄₄"...
  • Page 11 5. Attach the right and left end caps to the vent box. Place the Bottom Venting: tab into the mounting slot at each end of the downdraft vent NOTE: If installing the vent damper in the down position, a wall or as shown and push down to lock into place.
  • Page 12: Rear Mounting - Blower Motor

    Rear Mounting - Blower Motor NOTE: Optional blower motor rear mounting position (opposite 5. Remove the screws from the wire mounting plate. side) for island cabinet locations. The blower motor box assembly can be moved to the opposite side (rear) of the vent box.
  • Page 13: Complete Installation

    Complete Installation NOTE: The downdraft vent system is supplied with a 3¹⁄₄" x 10" 3. Determine which direction (front or rear) the home power (8.3 x 25.4 cm) back draft damper and a 6" (15.2 cm) round vent supply cable will enter the terminal box. Remove the transition with damper.
  • Page 14: Make Electrical Connections

    7. Fasten the lower support legs to the cabinet floor with screws 4. Connect the 2 white wires together using UL listed wire (not provided). connectors. A. Screw (not provided) 8. Tighten the lower support legs screws. Make Electrical Connections A.
  • Page 15: Vent System Use

    VENT SYSTEM USE The retractable downdraft vent system is designed to remove smoke, cooking vapors and odors from the cooktop area. Operating Downdraft Vent ■ For best results, the vent should be operating before cooking To Use: is started. 1. Push and hold the button on top of downdraft vent for a few ■...
  • Page 16: Wiring Diagram

    WIRING DIAGRAM Motor Specifications YL/GN Power supply 120 VAC Frequency 60 Hz Wattage rating 420 W Amperage 3.7 A Motor Resistance BU/WH 21.6 Ohms BU/RD 18 Ohms BU/GY 14.3 Ohms BU/BK 9.8 Ohms Blower Switch Operation Function Contact 1 - 3 N.O.
  • Page 17: Assistance Or Service

    ■ Scheduling of service. Jenn-Air ® appliances designated If you need further assistance, you can write to Jenn-Air ® service technicians are trained to fulfill the product warranty Appliances with any questions or concerns at: and provide after-warranty service anywhere in the United States.
  • Page 18: Warranty

    DISCLAIMER OF REPRESENTATIONS OUTSIDE OF WARRANTY Jenn-Air makes no representations about the quality, durability, or need for service or repair of this major appliance other than the representations contained in this warranty. If you want a longer or more comprehensive warranty than the limited warranty that comes with this major appliance, you should ask Jenn-Air or your retailer about buying an extended warranty.
  • Page 19: Sécurité Du Système De Ventilation

    SÉCURITÉ DU SYSTÈME DE VENTILATION Votre sécurité et celle des autres est très importante. Nous donnons de nombreux messages de sécurité importants dans ce manuel et sur votre appareil ménager. Assurez-vous de toujours lire tous les messages de sécurité et de vous y conformer. Voici le symbole d’alerte de sécurité.
  • Page 20 IMPORTANTES INSTRUCTIONS DE SÉCURITÉ AVERTISSEMENT : AVERTISSEMENT : POUR MINIMISER LE RISQUE POUR RÉDUIRE LE RISQUE D'UN FEU DE GRAISSE SUR LA CUISINIÈRE : D'INCENDIE, CHOC ÉLECTRIQUE OU DOMMAGES CORPORELS, RESPECTER LES INSTRUCTIONS ■ Ne jamais laisser un élément de surface fonctionner à SUIVANTES : puissance de chauffage maximale sans surveillance.
  • Page 21: Exigences D'installation

    EXIGENCES D'INSTALLATION Outils et pièces Exigences d’emplacement Rassembler les outils et pièces nécessaires avant d’entreprendre REMARQUE : Le système d’extraction par le bas est installé directement derrière la table de cuisson. Installer d’abord le l’installation. Lire et observer les instructions fournies avec système d’extraction par le bas, puis la table de cuisson.
  • Page 22 Dimensions du produit Largeurs de la garniture supérieure : 30" (76,2 cm) 36" (91,4 cm) 13¹⁄₂" (34,3 cm) hauteur de l’évacuation rétractable 1¹⁄₂" (3,8 cm) ³⁄₈" (0,95 cm) 27" (68,6 cm) pour une évacuation de 30" (76,2 cm) 33" (83,8 cm) pour une évacuation de 36"...
  • Page 23 Dimensions du placard 10" (25,4 cm) A = ½" (12,7 mm) minimum 21 ⁵⁄₁₆" (54,1 cm) 21⁵⁄₁₆" (54,1 cm) Dimensions des ouvertures indiquées pour des conduits d'évacuation rectangulaire de 3¼" x 10" (8,3 x 25,4 cm) ou circulaire de Axe central de l'ouverture 6"...
  • Page 24: Spécifications Électriques

    Tableau des dimensions de l’ouverture du plan de Exigences concernant travail l'évacuation IMPORTANT : Avant d'effectuer des découpes, s'assurer qu'il y a un dégagement convenable dans le mur ou le plancher pour le système d’extraction. ■ Utiliser un conduit métallique rigide. ■...
  • Page 25: Instructions D'installation

    INSTRUCTIONS D'INSTALLATION Méthodes d’évacuation Déterminer la méthode d’évacuation la plus appropriée. La sortie Configuration en îlot—Circuit d’évacuation installé à l’extérieur du circuit d’évacuation peut se faire à travers le sous une dalle de béton (utilisation de conduit de plancher ou à travers un mur. PVC pour égout) Configuration en îlot Ventilateur monté...
  • Page 26: Installation Du Conduit D'évacuation

    Exemple de circuit d’évacuation Calcul de la longueur effective du circuit d’évacuation 6 pi (1,8 m) Un conduit rectangulaire de 3¼" x 10" (8,3 x 25,4 cm) est nécessaire pour la caisse du ventilateur. Il peut être raccordé à un conduit rond de 6" (15,2 cm) si nécessaire. 2 pi (0,6 m) Longueur maximum du circuit d’évacuation Conduit d’évacuation...
  • Page 27 5. Fixer les embouts à droite et à gauche sur la caisse du Évacuation par le bas : système d’extraction. Placer la languette dans la rainure REMARQUE : Si le clapet anti-retour est monté vers le bas, une de montage à chaque extrémité de la caisse du système bouche de décharge murale ou à...
  • Page 28: Montage Du Ventilateur À L'arrière

    Montage du ventilateur à l'arrière REMARQUE : Position de montage du ventilateur à l’arrière (côté 5. Retirer les vis de la platine de montage du câble. opposé) possible pour les configurations en îlot. On peut déplacer la caisse du moteur du ventilateur du côté opposé (arrière) de la caisse du système d’extraction.
  • Page 29: Achever L'installation

    Achever l’installation REMARQUE : Le système d’extraction par le bas est livré avec 2. Ôter les 4 vis du couvercle du boîtier de connexion. un clapet anti-retour de 3¹⁄₄" x 10" (8,3 x 25,4 cm) et un raccord de transition pour conduit rond de 6" (15,2 cm) avec clapet. Se reporter à...
  • Page 30: Raccordements Électriques

    5. Percer 2 avant-trous à travers les équerres de fixation sous le AVERTISSEMENT plan de travail, dans la face inférieure du plan de travail. Avec 2 vis (non fournies) de la longueur adéquate, fixer les équerres au plan de travail. IMPORTANT : Choisir des vis d’une longueur adéquate pour ne pas traverser le plan de travail au serrage.
  • Page 31: Contrôle Du Fonctionnement

    Contrôle du fonctionnement 1. Appuyer pendant quelques secondes sur le bouton au 2. Manœuvrer le curseur de commande sur le côté de l’appareil sommet du système d’extraction par le bas. La partie pour vérifier son fonctionnement et la vitesse du ventilateur. rétractable du système d’extraction par le bas se soulève, 3.
  • Page 32: Entretien Du Système D'évacuation

    ENTRETIEN DU SYSTÈME D’ÉVACUATION Nettoyage : Surface du système d’extraction 1. Nettoyer le(s) filtre(s) au lave-vaisselle ou dans une solution de détergent chaude. Le système d’extraction par le bas par le bas ne fonctionne pas lorsque les filtres ne sont pas installés. Pour éviter d’endommager la finition, nettoyer les surfaces avec 2.
  • Page 33: Schéma De Câblage

    SCHÉMA DE CÂBLAGE Caractéristiques du moteur Alimentation 120 VCA JA/VE Fréquence 60 Hz Puissance nominale 420 W Intensité 3,7 A Résistance du moteur BU/BL 21,6 ohms BU/R 18 ohms BU/GRIS 14,3 ohms BU/N 9,8 ohms GRIS GRIS Fonctionnement du commutateur du ventilateur Contact Fonction 1 - 3...
  • Page 34: Assistance Ou Service

    Pour les modèles séries JXD7030Y Téléphoner sans frais au Centre pour l'eXpérience de la clientèle Garniture supérieure monopièce de 30" (76,2 cm) Whirlpool Canada LP au 1-800-JENN-AIR (1-800-536-6247) ou visiter notre site Internet sur www.jennair.ca. Commander la pièce numéro W10387676 (noir) Nos consultants peuvent vous aider sur les points suivants : Pour les modèles séries JXD7036Y...
  • Page 35: Garantie

    EXONÉRATION DE RESPONSABILITÉ DANS LES DOMAINES NON COUVERTS PAR LA GARANTIE Jenn-Air décline toute responsabilité au titre de la qualité, de la durabilité ou en cas de dépannage ou de réparation nécessaire sur ce gros appareil ménager autre que les responsabilités énoncées dans la présente garantie. Si vous souhaitez une garantie plus étendue ou plus complète que la garantie limitée fournie avec ce gros appareil ménager, adressez-vous à...
  • Page 36 3/15 ® /™ ©2015 Jenn-Air. Used under license in Canada. All rights reserved. Printed in Mexico W10342490E Utilisé sous licence au Canada. Tous droits réservés. Imprimé au Mexique...

Table of Contents