Jenn-Air JXD7036YS0 Use & Care Manual

30" (76.2 cm) and 36" (91.4 cm) retractable (pop-up) downdraft vent system installation instructions
Table of Contents

Advertisement

Available languages

Available languages

Quick Links

30"(76.2 CM) AND 36"(91.4 CM)
RETRACTABLE (POP-UP)DOWNDRAFT VENTSYS'EM
SYSTEME DEVENTILATION RIr::TRACTABLE
(CLAPE'I)DE
30" (76,2 CM) ET36" (91,4 CM) - ASPIRATION
PARLEBAS
Installation Instructions a nd Use& Care Guide
For questions about features, operation/performance,
parts, accessories, or service in the U.S.A., call:
1-800-JENNAIR
(1-800-536-6247),
or visit our website at www.jennair.com.
In Canada, call: 1-800-807-6777,
or visit our website at www.jennair.ca.
Instructions d'installation et Guide d'utilisation et d'entretien
Au Canada, pour assistance, installation ou service, composez le 1-800-807-6777
ou visitez notre site web & www.jennair.ca.
Table of Contents/Table
des matieres ....................... 2
IMPORTANT: READ AND SAVE THESE INSTRUCTIONS.
FOR RESIDENTIAL
USE ONLY.
IMPORTANT : LIRE ET CONSERVER CES INSTRUCTIONS.
POUR UTILISATION
Ri_SIDENTIELLE
UNIQUEMENT.
JENN-AIR °
LI3ZVB/W103424900

Advertisement

Table of Contents
loading

Summary of Contents for Jenn-Air JXD7036YS0

  • Page 1 Au Canada, pour assistance, installation ou service, composez le 1-800-807-6777 ou visitez notre site web & www.jennair.ca. Table of Contents/Table des matieres ....... 2 IMPORTANT: READ AND SAVE THESE INSTRUCTIONS. FOR RESIDENTIAL USE ONLY. IMPORTANT : LIRE ET CONSERVER CES INSTRUCTIONS. POUR UTILISATION Ri_SIDENTIELLE UNIQUEMENT. JENN-AIR ° LI3ZVB/W103424900...
  • Page 2: Table Of Contents

    TABLE OF CONTENTS VENT SYSTEM SAFETY ..............Check Operation ................ INSTALLATION REQUIREMENTS ..........VENT SYSTEM USE ..............Tools and Parts ................Operating Downdraft Vent ............Location Requirements ..............VENT SYSTEM CARE ..............Electrical Requirements ............... Surface of Downdraft Vent ............Venting Requirements ..............
  • Page 3 iMPORTANT SAFETY iNSTRUCTiONS WARNING: TO REDUCE THE RISK OF A RANGE TOP WARNING: TO REDUCE THE RISK OF FIRE, ELECTRIC GREASE FIRE: SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING: [] Never leave surface units unattended at high settings. Boilovers cause smoking and greasy spillovers that may [] Use this unit only in the manner intended by the ignite.
  • Page 4: Installation Requirements

    INSTALLATION REQUIREMENTS Gather the required tools and parts before starting installation. Parts Supplied Read and follow the instructions provided with any tools listed • Top trim--stainless here. • End caps (2) • Lower support legs (2) Tools Needed • Undercounter mounting brackets (2) •...
  • Page 5 Product Dimensions Top trim widths: 30" (76.2 cm) 36" (91.4 cm) 131/2`' (34.3 cm) retractable vent height (0.95 cm) 27" (68.6 cm) for 30" (76.2 cm) vent 33" (83.8 cm) for 36" (91.4 cm) vent 51/4"(13.3 cm) for 30" (76.2 cm) vent (21.0 cm) for 36"...
  • Page 6 Countertop Cutout Dimensions IMPORTANT: Countertops with a bull-nosed front edge are not recommended for these installations. Some models require a countertop deeper than 25" (63.5 cm); see the following "Countertop Cutout Dimensions Chart." To avoid mistakes, it is recommended that the cooktop and vent cutouts be drawn on the countertop before making any cutouts. See the Installation Instructions that came with your cooktop for complete cutout dimensions, location dimensions and installation details.
  • Page 7: Electrical Requirements

    Observe all governing codes and ordinances. • If the house has aluminum wiring, follow the procedure below: Ensure that the electrical installation is adequate and in conformance with National Electrical Code, ANSI/NFPA 70 (latest 1. Connect a section of solid copper wire to the pigtail leads.
  • Page 8: Installation Instructions

    INSTALLATION INSTRUCTIONS Determine which venting method is best for your application. Island Location--Vent System Installed Under a Concrete Vent system can terminate either through the wall or floor. Slab Using PVC Sewer Pipe Island Location Front (Standard) Mounted Blower Motor Rear-Mounted Blower Motor Front (Standard)-Mounted...
  • Page 9: Install Vent System

    To calculate the length of the system you need, add the Example Vent System equivalent feet (meters) for each vent piece used in the system. 31/4'' x 10" (8.3 cm x 25.4 cm) Vent Piece Rectangular 31/4"x 10" (8.3 cm x 25.4 cm) 5.0 ft 2 ft (0.6 m) 90 °...
  • Page 10 Install the right and left undercounter mounting brackets to Attach the support legs to the side of the vent box with the vent box. Slide the keyhole slots over the guide tabs and 4 - 4 x 8 mm screws in each support leg. Adjust to dimension "Y"...
  • Page 11: Rear Mounting--Blower

    Left or Right Venting: Mo$o 1. Using two or more people, place the downdraft vent system on its back. NOTE: Optional blower motor rear mounting position (opposite 2. Remove the 4 screws from the cover plate mounted to the side) for island cabinet locations. The blower motor box face of the motor box and set them aside.
  • Page 12: Complete Installation

    4. Lift the 1¼,, ( 6.4 mm) deep cover off the shoulder screws in the keyhole slots and set the cover aside. 5. Remove the screws from the wire mounting plate. NOTE: The downdraft vent system is supplied with a 3¼" x 10" (8.3 x 25.4 cm) back draft damper and a 6"...
  • Page 13: Make Electrical Connections

    2. Remove 4 screws attaching the terminal box cover. Drill 2 pilot holes through each of the undercounter mounting brackets into the underside of the countertop. Using 2 screws (not provided) of the appropriate length, mount the brackets to the countertop. IMPORTANT: Select a screw length that will not allow the screws to go through the countertop when tightened.
  • Page 14: Check Operation

    2. Feed the power supply cable through the conduit connector 5. Connect the 2 black wires together using UL listed wire and into the terminal box. connectors. 6. Replace the terminal box cover and secure with screw. 7. Reconnect power. Push and hold the button on the top of the downdraft vent for a few seconds.
  • Page 15: Operating Downdraft Vent

    To Use: If a spill occurs on the cooktop that allows liquids to seep inside Push and hold the button on top of downdraft vent for a few the downdraft vent, you must turn the downdraft vent off seconds, (This slight delay helps avoid unintentional raising immediately.
  • Page 16: Wiring Diagram

    WIRING DIAGRAM © Motor Specifications Power supply 120 VAC Frequency 60 Hz Wattage rating 420 W Amperage 3.7 A Motor Resistance BU/W 21.6 Ohms BU/R 18 Ohms BU/GY 14.3 Ohms ® BU/BK 9.8 Ohms ® %_,_° © Blower Switch Operation Function Contact 1st Speed...
  • Page 17: Assistanceor Service

    Benton Harbor, MI 49022-2692 5. Proof of purchase (sales receipt). Web address: www.jennair.com User's guides, service manuals and parts information are available from Jenn-Air Brand Home Appliances, Customer Or call: 1-800-536-6247 eXperience Center. Call the dealer from whom your appliance was purchased, or call...
  • Page 18: War Ranty

    For one year from the date of purchase, when this major appliance is operated and maintained according to instructions attached to or furnished with the product, Jenn-Air brand of Whirlpool Corporation or Whirlpool Canada LP (hereafter "Jenn-Air") will pay for factory specified parts and repair labor to correct defects in materials or workmanship.
  • Page 19: Securite Du Systeme De Ventilation

    SECURITE DU SYSTEME DEVENTILATION Votre securite et celle des autres est tres importante. Nous donnons de nombreux messages de s_curit_ importants dans ce manuel et sur votre appareil m_nager. Assurez-vous toujours lire tousles messages de s_curit_ et de vous y conformer. Ce symbole d'alerte de s_curit_ vous signale les dangers potentiels de d_c_s et de blessures graves &...
  • Page 20 llVlPORTANTES iNSTRUCTiONS DE Sl CURITl AVERTISSEMENT : POUR MINIMISER LE RISQUE AVERTISSEMENT : POUR REDUIRE LE RISQUE D'UN FEU DE GRAISSE SUR LA CUISINIF:RE : D'INCENDIE, CHOC ELECTRIQUE OU DOMMAGES CORPORELS, RESPECTER LES INSTRUCTIONS [] Ne jamais laisser un 616ment de surface fonctionner & SUIVANTES puissance de chauffage maximale sans surveillance.
  • Page 21: Exigences D'installation

    EXIGENCESD'INSTALLATION [)IG, COS Pi_ces fournies Rassembler les outils et pieces necessaires avant d'entreprendre I'installation. Lire et observer les instructions fournies avec • Garniture superieure--acier inoxydable chacun des outils de la liste ci-dessous. • Embouts (2) • Pieds de soutien inferieurs (2) Outillage n_cessaire •...
  • Page 22 Dimensions du produit Largeurs de la garniture 30" (76,2 cm) supdrieure: 36" (91,4 cm) 131/2" (34,3 hauteur de I'_vacuation r_tractable 27" (68,6 cm) pour une _vacuation de 30" (76,2 cm) 33" (83,8 cm) pour une _vacuation de 36" (91,4 cm) 51/4`' (13,3 cm) pour une _vacuation de 30"...
  • Page 23 Plan de travail--Dimensions des ouvertures _ d_couper IMPORTANT : Les plans de travail avec rebord avant arrondi ne sont pas recommandes pour ces installations. Certains modeles necessitent un plan de travail de plus de 25" (63,5 cm); voir le tableau des dimensions de I'ouverture du plan de travail.
  • Page 24: Specifications Electriques

    Observer les dispositions de tousles codes et reglements en • Si le domicile possede un c&blage en aluminium, suivre la vigueur. procedure ci-dessous : Raccorder une section de c&ble en cuivre massif aux S'assurer que I'installation electrique est correcte et qu'elle conducteurs en queue de cochon.
  • Page 25: Instructions D'installation

    INSTRUCTIONS D'INSTALLATION Configuration en lot-Circuit d'6vacuation install_ sous Determiner la methode d'evacuation la plus appropriee. La sortie une dalle de b_ton (utilisation de conduit de PVC pour & I'exterieur du circuit d'evacuation peut se faire a travers le _gout) plancher ou & travers un mur. Configuration en lot Ventilateur mont_ &...
  • Page 26: Installation Du Conduit D'evacuation

    Pour calculer la Iongueur effective du circuit d'evacuation Exemple de circuit d'_vacuation necessaire, additionner les Iongueurs equivalentes (en pieds ou metres) de tous les composants utilises dans le circuit. (1,8 m) Rectangulaire de 31/4 '' x 10" Composant (8,3 cm x 25,4 cm) 2 pi (0,6 m) Raccord coude &...
  • Page 27 Installer sur la caisse du systeme d'extraction les equerres Fixer les pieds de soutien aux c6tes de la caisse du systeme droite et gauche de montage sous le plan de travail. Inserer d'extraction avec 4 vis de 4 x 8 mm pour chacun. Les regler les encoches en trou de serrure dans les languettes guides et la distance "Y"...
  • Page 28: Montage Du Ventilateur & I'arriere

    Sortie par le c6t_ gauche ou le c6t_ droit : 1. A deux personnes ou plus, poser I'arriere du systeme ,Ill _Ss ' I_Y °' '_5_ I d'extraction par le bas face au sol. REMARQUE : Position de montage du ventilateur i I'arriere (cite 2.
  • Page 29: Achever I'installation

    4. Lever le couvercle d'epaisseur 1/4"(6,4 mm) pour le sortir des o fon vis & epaulement dans les encoches en trou de serrure et le mettre de c6te. RI=MAROUI= : Le systeme d'extraction par le bas est livre avec 5. Retirer les vis de la platine de montage du c&ble. un clapet anti-retour de 31/4"x 10"...
  • Page 30: Raccordements Electriques

    2. Oter les 4 vis du couvercle du boftier de connexion. IMPORTANT : Choisir des vis d'une Iongueur adequate pour ne pas traverser le plan de travail au serrage..... _'ii i ,/,/ A. Vis B. Panneau anti-_claboussure A. Couvercle du boftier de connexion C.
  • Page 31: Contr61E Du Fonctionnement

    6. Reinstaller le couvercle du boitier de connexion et le fixer 2. Faire passer le c&ble d'alimentation & travers le connecteur de conduit et dans le boitier de connexion. avec la vis. 7. Reconnecter la source de courant electrique. (,i;, S;xsc 'sot£sneme s "...
  • Page 32: Utilisation Du Systeme D'extraction Par Le Bas

    Uti s<sfion s/® d ®xt c ;ct o n y ......Utilisation : NOTE: Si du liquide renverse s'infiltre dans le systeme d'extraction par le bas, I'appareil doit _tre arr_te 1. Appuyer pendant quelques secondes sur le bouton au immediatement.
  • Page 33: Schema De C,&,Blage

    SCHI MA DECABLAGE © Caract6ristiques du moteur Alimentation 120 VCA JA!VE Fr6quence 60 Hz Puissance nominale 420 W Intensit6 3,7 A R6sistance du moteur BU/BL 21,6 ohms BU/R 18 ohms BU/GRIS 14,3 ohms BU/N 9,8 ohms ® ® --O°° © o_ To GRIS GRIS...
  • Page 34: Assistance Ou Service

    Cc aosdc Telephonez au marchand qui vous a vendu I'appareil ou REMARQUE : Pour toute correspondance ou appel au sujet d'un telephonez & Jenn-Air en composant le 1-800-807-6777 pour probleme de service, veuillez inclure les renseignements suivants : Iocaliser une compagnie de service autorisee. Lors d'un appel, veuillez connaitre la date d'achat et les numeros de modele et de 1.
  • Page 35: Au Canada

    CONF#RE DES DROITS JURIDIQUES SPI2CIFIQUES ET VOUS POUVEZ 12GALEMENT JOUIR D'AUTRES DROITS QUI PEUVENT VARIER D'UNE JURIDICTION A UNE AUTRE. Si vous residez & I'exterieur du Canada et des 50 12tats des 12tats-Unis, contactez votre marchand Jenn-Air autorise pour determiner si une autre garantie s'applique.
  • Page 36 Printed in Mexico. All rights reserved. ® Registered Trademark/TM Trademark of Jenn-Air, U.S.A. Used under license by Maytag Limited in Canada. Tous droits reserves. ®Marque deposee/TM Marque de commerce de Jenn-Air, U.S.A. Emploi sous licence par Maytag Limited au Canada.

This manual is also suitable for:

Jxd7030ys0W10342490c

Table of Contents