Performance Data Sheet
SmartWater FiltrationSystem
GSWFCartridge
This systemhas been testedaccording to NSF/ANSI 42/53for reductionof the substanceslisted below.
The concentrationof the indicated substancesin water enteringthe system was reduced to a concentration
less than or equal to the permissiblelimit for water leaving the system,as specified in NSF/ANS/ 42/53. _
(100% safety factors built in for unmetered usage)
Standard
No. 42: Aesthetic
Effects
Parameter
Chlorh_e
T&,O
Particulate
'l:*
Parameter
Tu_Sidit}
()_ts
[_ead at pH 6.5
[_ead at pH 8.5
[ Jndane
Atrazine
USEPA
Influent
MCL
Average
--
1.845 mg/L
,
'2, o
--
143,.,3:,#/mL
USEPA
MCL
1 NTU***
99.95% Reduction
11.1115 mg/L
0.015 mg/L
0.0002 mg/L
0.003 mg/L
Irdluent Challenge
Concentration
2.0
rag/L_+10%
at least 10,000 particles!rot
29.83 #/mL
Standard
No. 53: Health
Effects
Influent
Average
10.3 NTU***
200,000 #/L
0.15 mg/L
0.14 mg/L
0.0216
mg/L
0.008 mg/L
Influent Challenge
Concentration
1+_1NTU***
Minimum 50,000 [
0.15 mg/i al 0%
0.15 mg/i al 0%
0.002 mg/i al 0%
0.009 mg/i_+l 0%
Effluent
Average
Maximum
< 0.05 mg/L
0.05 mg/L
140 #/mL
Effluent
Average
0.106 NTU
0
< 0.001 mg/L
0.00l mg/L
< 0.00002 mg/L
< 0.002 mg/L
M_LX_d_lunl
0.14 NTU
o
< o.ool
mg/L
0.003
mg/L
< 0.00002
mg/L
< 0.002
mg/L
% Reduction
Average
Minimum
> 97.29%
96.43%
99.98%
99.91%
% Reduction
Average
Minimum
98.97%
98.61%
> 99.99%
> 99.99%
> 99.33%
> 99.33%
> 99.29%
97.8t;%
99.07%
98.75%
> 76.12%
> 66.67%
Min,
Required
Reduction
>_ 5O%
>_ 85%
Min, Reqnired
Reduction
0.5 NTU
> t)9.t)5%
0.0l 0 mg/L
0.0l 0 mg/L
0.0002 mg/L
0.003 mg/L
* Testedusing a flow rate of 0.5 gpm;pressureof 60 ps/g;pH of 7.5+_ O. 5 ; temp. of 68° +_ 5°F (20° +_ 3°C)
__Measurement i n Particles/ml.Particlesusedwere0.5-1microns
......... NTU=Nephelometric Turbidity units
Operatino Specifications
It Capacity:
certified
for up to 750 gallons
(2,838 l); up to six months
m Pressure
requirement:
40-120
psi (2.8-8.2
bar)
It Temperature:
33-100°F
(0.6-38°C)
It Flow rate: 0.5 gpm
(1.9 lpm)
General Installation/Operation/Maintenance
Requirements
It Fhtsh new cartridge
at fitll flow for 3 minutes
to purge
out trapped
air.
It Replace
cartridge
when
flow becomes
too slow.
Special Notices
It Installation
instructions,
parts
and service
availability;
and standard
warranty
are inchtded
with the product
when
shipped.
It This drinking
water system
must be maintained
according
to manufacturer's
instructions,
including
replacement
of filter
cartridges.
It Do not use with water that is microbiologically
unsafe
or of tmknown
qttali W without
adequate
disin%ction
before
or
after the system.
Systems
certified
for cyst reduction
may be used on disin%cted
water that may contain
filterable
cysts.
It The contaminants
or other
substances
removed
or reduced
by this water
treatment
system
are not necessarily
in your
water.
It Check
for compliance
with the state and
local laws and regulations.
It Note
that while the testing
was perfbrmed
under
standard
laborato_
T conditions,
actual
performance
may vasT. Systems
must
be installed
and operated
in accordance
with manufacturer's
recommended
procedures
and guidelines.
System
tested
and
certified
b) NSF International
against
Standard
42 fi)r the
reduction
of
chh)rine,
taste
and
odor,
particulate
Class ] and
Standard
53 fl)r the
red uction
of cyst
lead,
[Jndane,
Atrazine
and
turbidit}.
Manutilctured
fi)r: General
Electric
Compan),