Performance
Data Sheet
Smart Water Filtration
System
GSWF Cartridge
This system has been tested according
to NSF/ANS142/53
for reduction
of the substances
listed below.
The concentration
of the indicated
substances
in water
entering
the system
was reduced
to a concentration
less than or equal to the permissible
limit for water leaving
the system,
as specified
in NSF/ANS142/53.
*
(700% safety f_ctors built in for unmetered
usage)
Parameter
USEPA
MCL
hfluent
Average
1.845 mg/L
143,333 #/mL
Standard No.
Lnfluent Challenge
Concentration
2.0mg/L_+ 10%
at. least. 10,000 particles/m[
2: Aesthetic Effects
EfflL ;nt
Average
Maximum
< 0.05 mg/L
0.05 mg/L
29.83 #/mL
140 #/mL
% Red _ction
Average
Minimum
> 97.29%
96.43%
99.98%
99.91%
I
Min. Required
Reduction
> 50%
Chlorine
T&O
Particulote**
> 85%
I
Standard
i_Io. 53: Health
Effects
Parameter
USEPA
Influent
Influent Challenge
Efflu{ nt
% RedL ction
Min. Required
MCL
Average
Concentration
Average
Maximum
Average
Minimum
Reduction
Turbidity
1 NTU***
10.3NTU***
1+1NTU***
0.106NTU
0.14NTU
98.97%
98.61%
0.5NTU
Cysts
99.95% Reduction
200,000 #/L
Minimum 50,000 [
0
0
> 99.99%
>99.99%
>99.95%
Lead
at pH
6.5
0.015
mg/L
0.15
mg/L
0.15
mg/L_+10%
< 0.001
mg/L
< 0.001
mg/L
>99.33%
>99.33%
0.010
mg/L
Lead
at pH
8.5
0.015
mg/L
0.14
mg/L
0.15
mg/L_+10%
0.001
mg/L
0.003
mg/L
>99.29%
97.86%
0.010
mg/L
Lindane
0.0002
mg/L
0.0216
mg/L
0.002 mg/L_+10%
<0.00002
mg/L
< 0.00002 mg/L
99.07%
98.75%
0.0002
mg/L
Atrazine
0.003
mg/L
0.008 mg/L
0.009 mg/L_+10%
< 0.002
mg/L
< 0.002
mg/L
> 76.12%
>66.67%
0.003
mg/L
Tested using a flow rate of O,5 gpm; pressure
of 60 ps(q,' pH of Z 5 + O,5; temp, of 68 _"+ 5_F (20 _" _ 3 _'C)
* Measurement
in Particles/mL
Particles used were O,5- 7 microns
_** NTU Nephelometric
Turbidity units
Operating
Specifications
m Capacity: certified for up to 750 gallons (2,838 I); up to six months
m Pressure requirement:
40-120
psi (2.8-8.2 bar)
" Temperature:
33-100°F
(0,6-38°C)
_' Flow Fate: 0,5 gpm (1,9 Ipm)
General
Instaflation/Operation/Maintenance
Requirements
m Flush new cartridge
at full flow for 3 minutes to purge out trapped
air,
m Replace cartridge
when flow becomes
too slow,
Special
Notices
m Installation
instructions,
parts and service availability,
and standard
warranty
are included with the product when shipped,
,, This drinking water system must be maintained
according
to manufacturer's
instructions,
including
replacement
of filter
cartridges,
,, Do not use with water that is microbiologically
unsafe or of unknown
quality without
adequate
disinfection
before or after
the system, Systems certified for cyst reduction
may be used on disinfected
water that may contain filterable
cysts,
,, The contaminants
or other substances
removed
or reduced by this water treatment
system are not necessarily
in your water,
,, Check for compliance
with the state and local laws and regulations,
,, Note that while the testing was performed
under standard
laboratory
conditions,
actual performance
may vary, Systems
must be installed and operated
in accordance
with manufacturer's
recommended
procedures
and guidelines,
System
tested
and certified
by NSF International
against
Standard
42 for the reduction
of
chlorine,
taste
and odor, particulate
Class I and Standard
53 for the reduction
of cyst, lead,
Lindane,
Atrazine
and turbidity.
Manufactured
for: General
Electric
Company,
Louisville,
KY 40225
]