Lp Fuel Tank Installation - Briggs & Stratton 40248 Operator's Manual

7kw dual-mode backup generator
Hide thumbs Also See for 40248:
Table of Contents

Advertisement

Available languages

Available languages

E
LP Fuel Tank Installation
iMPORTANT:
To ensure optimal
performance,
use two
(2) LP fuel tanks
during operation.
This section describes the proper
method of installing and
leak testing the generator's
LP fuel tanks. This system is
supplied with an LP fuel tank cover. Always cover the LP
fuel tanks whenever they are connected
to the generator.
WARNING
The slightest
spark can ignite this fuel and cause an explosion.
IF YOU SNELL GAS - Shut off gas to the generator
at the LP fuel
tank(s).
If odor
continues,
leave the area and immediately
call your
gas
supplier
or fire department.
To
I.
.
install LP Fuel Tanks:
Confirm
both LP fuel tank shut off valves are dosed
(turned fully CLOCKWISE).
Place each LP tank into the LP tank tray with it's fuel
valve pointing towards
the generator
(see Figure 5).
B
Figure 5 --
Proper Position for LP Fuel Tanks
A - LP Fuel Tank Shut Off Valve Connector
B - LP Fuel Tank
.
Slide the LP fuel tank hold-down
bracket
onto the
threaded
rod. Position
the bracket
so that its notches
are aligned with both LP fuel tank collar holes, as
shown
in Figure 6.
.
It may be necessary
to "wiggle"
the LP fuel tanks and
the bracket
to obtain proper
alignment.
Slide the fuel hose/regulator
assembly
over the
threaded
rod so that it faces the generator
and rests
on the hold-down
bracket
(see Figure 7).
Figure 7 --
Fuel Hose/Regulator Assembly Placement
A - Hold-Down Bracket
B - Threaded Rod
C - Fuel Hose/Regulator Assembly
Thread
the wing nut CLOCKWISE
onto the threaded
rod. Hand tighten
wing nut against fuel hose/regulator
assembly,
ensuring
hold-down
bracket
notches
remain
engaged with LP fuel tank collars
and LP fuel tanks are
held firmly. See Figure 8.
Figure 8 --
Properly-Secured LP Fuel Tanks
A - LP Fuel Tank
B - Wing Nut
C - Fuel Hose/Regulator Assembly
6.
Remove
protective
covers
from both LP fuel tank shut
off valve connectors.
DO NOT discard
protective
covers
- they should be installed any time the LP fuel
tank is disconnected
from the generator.
7.
Insert the nipple of the left connection
device (as you
face the generator
and LP fuel tanks)
into the left LP
fuel tank valve outlet
(see Figure 9). Ensure it is fully
inserted.
Figure 6 --
Properly-Aligned Hold-Down Bracket
A - Bracket Notch over Fuel Tank Collar
B - Hold-Down Bracket
8
www.briggsan
dstratton.com