The room containing the cooker should have an air supply in accordance with BS.5540:
Part 2: 1989.
All rooms require an openable window or equivalent while some rooms require a per-
manent vent in addition to the openable window.
The cooker should not be installed in a bed-sitting room, of volume less than 21 m
Where a DOMESTIC COOKER is installed in a room or internal space, that room or
internal space shall be provided with a permanent opening which communicates directly
with outside air and is sized in accordance with table below. In domestic premises the
permanent opening shall be an air vent.
If there are other fuel burning appliances in the same room, BS.5540: Part 2: 1989
should be consulted to determine the requisite air vent requirements.
If the cooker is installed in a cellar or basement, it is advisable to provide an air vent
of effective area 100 cm
MINIMUM PERMANENT OPENING FREE AREA FOR FLUELESS APPLIANCE
Type of appliance
Domestic oven, hot-
plate, grill or any
combination thereof.
If the room or internal space containing these appliances has a door which
( )
opens directly to outside, no permanent opening is required.

Provision for ventilation

2
, irrespective of the room volume.
Maximum
appliance
< 5 m
rated
input limit
100
None
cm
Room volume
3
5 m
to
11 m
3
3
10 m
20 m
Nil
50 ( )
2
2
cm
cm
Openable
window or
3
to
3
> 20 m
equivalent also
3
required
Nil
2
2
cm
3
.
Yes
9