CCD Scanner
UPC Settings (continued)
Options for UPC-A - The UPC-A symbology is a fixed length symbology encoding 11 data digits, a check digit
and non printable start/stop characters. Supported characters are numeric digits 1 to 9.
An optional leading zero can be transmitted which, together with the data and the check digit, forms a 13 digit field
providing compatibility with the EAN-13 format.
String format:
UPC-A add-on 2/add-on 5 - The UPC-A symbology as described above can be succeeded by an additional 2 or 5
digit UPC-A code.
String format:
Options for UPC-A
*
Disable transmission of the leading zero
*
Disable transmission of the check digit
Options for UPC-E - The UPC-E symbology is a fixed length symbology encoding 6 data digits, a check digits and
non printable start/stop characters. Supported characters include numeric digits 0 to 9. An optional leading zero can
be transmitted which, together with the data and the check digit, forms an 8 digit field providing a compatibility with
the EAN-8 format.
String format:
UPC-E add-on 2/add-on 5 - The UPC-E symbology as described above can be succeeded by an additional 2 or 5
digit UPC-A code.
String format:
Options for UPC-E
*
Enable transmission of the leading zero
*
Disable transmission of the check digit
*
Transmit UPC-E as UPC-A
Leading
data
0
(11 digits)
Leading
data
0
(11 digits)
Leading
data
0
(6 digits)
Leading
data
0
(6 digits)
Series OPT Handheld
check
digit
check
add-on
digit
2 or 5
check
digit
check
add-on
digit
2 or 5