FNC2 Concatenation - If a Code 128 bar code contains a leading FNC2 character, the data is stored into the
reader's buffer. As soon as a Code 128 bar code is read without a leading FNC2 character, the data is appended to
the reader's buffer and the entire buffer is transmitted and cleared for new data. In case a non Code 128 bar code is
read, the data in the non-Code 128 bar code is transmitted and the buffer is cleared. The buffer size is reader
dependent.