Chassisinstallation - Friedrich WallMaster PTAC Installation & Operation Manual

Ptac packaged terminal air conditioners & heat pumps
Hide thumbs Also See for WallMaster PTAC:
Table of Contents

Advertisement

920-087-02
(9-03)
Section III - ChassisInstallation
* Check to be sure the wall sleeve, extension (if used), grille, and drain kit are installed properly before
chassis installation
1. Remove the weatherboard and center support from
the sleeve (if still in place). Be sure an outdoor grille is
attached.
NOTE: To avoid breaking the door or hinge pins, do not apply
excessive force when installing
_
Pins
Wall sleeve
/
Control
Door
--
Weatherboard
Center support
Front Panel
3. Remove the two chassis shipping brackets from the ends of
the shipping pallet.
IMPORTANT:Use awa]]sleeveadapterkit(PXSE)if
installing a P-Series chassis in a T-Series sleeve.
Suffocation hazard
Keep bag away from babies and children.
Do NOT use in cribs, beds or playpens.
Destroy
immediately after opening. This oag is NOT a toy.
Failure to do so can result in personal injury end/or death
2. Remove the front cover contained in a protective plastic bag
from chassis. Remove the bag and dispose of it properly.
If the control door is not installed, f ollow these steps:
From the front of the cover, slide the right control door pin into
the hole on the right side of the front cover. Slide the left door
pin into the hole on the left side of the front cover opening and
snap it intoplace.
@
Compressor
Chassis
shipping bracket
Shipping pallet
IMPORTANT: When installing a Friedrich P-Series PTAC intoan
existing sleeve, it is important to ensure that the unit is installed
completely. Inspection of the air seal between the condenser air
baffles and around the indoormounting flange isrecommended. In
some cases additional gaskets or baffling may be required.