Drainkit Installation - Friedrich WallMaster PTAC Installation & Operation Manual

Ptac packaged terminal air conditioners & heat pumps
Hide thumbs Also See for WallMaster PTAC:
Table of Contents

Advertisement

920-087-02 (9-03)
ExtemalDrain(for newconstructionor unit replacement)
When using an external drain system, the condensate is removed through either of two drain holes on the back of the wall sleeve. Select
the drain hole which best meets your drainage situation and install the drain kit. Seal off the other with a cover plate.
Drain Tube Installation
1.
Peel the backing tape off the gaskets and apply the sticky
side to one cover plate and one mounting plate as shown
in Details A and B,
2.
Place the drain tube through the gasket and the mounting
plate with the flange toward the wall sleeve.
3.
Attach the drain tube assembly to one of the two drain
holes at the rear of the wall sleeve. The large flange on
the mounting plate is positioned atthe bottom of the sleeve
facing toward the sleeve, Detail B. When the drain tube is
positioned at the desired angle, tighten the screws.
NOTE: If the wall sleeve has not been installed,the drain tube must
be rotated to a horizontal position until after the sleeve
is installed. Tighten the mounting plate screws when the
tube is in the proper position. Make certain that the four
overflow slotsat the rear of the wall sleeve are not blocked.
(See the drawing below.)
Cover Plate Installation
4.
Mountthefoamgaskettothecoverplate.
Usingtwo#10x
1/2" sheet metal screws (provided), attach the cover plate
to the remaining drain hole. Make certain the large flange
on the plate is positioned at the bottom of the sleeve.
5.
Discardthe additionalcover plate,gasket, machine screws,
and Iocknuts.
QUANTITY
DESCRIPTION
2
1
1
3
4
2
2
COVER PLATES
MOUNTING PLATE
DRAIN TUBE
MOUNTING PLATE GASKETS
#10 X 1/2" MOUNTING SCREWS
10-24 X 1/2" MACH, SCREWS
LOCKNUTS
Figure 4
Drain Kit Installation
gasket
plate
DETAIL A
Foam gasket
_
_/2" O .D.tube
Mounting plate
#10 sheet metal screws
_DETAIL
B
NOTES:
The large flange on the mounting plate is positioned at the bottom of the sleeve facing toward the sleeve. The drain tube must be rotated to a horizontal
position to allow for the wall sleeve to be installed into the wall. Once the wall sleeve is installed, return the drain tube to a downward angle.
6