Craftsman 113.213130 Owner's Manual page 6

Motorized 13-inch floor model drill press
Table of Contents

Advertisement

motor specifications
electrical
i,
MOTOR SPECiFICATiONS
ThiS drili press is designed to use a 1725 RPM motor
only. Do not use any motor that runs faster than t725
RPM, It is wired for operation on 1 t 0-120 volts, 60 Hz.
alternating current.
WARNING:
TO
AVOID
INJURY
FROM
UNEX-
PECTED STARTUP, DO NOT USE BLOWER OR
WASHING
MACHINE
MOTORS OR ANY MOTOR
WiTH AN AUTOMATIC
RESET OVERLOAD
PRO-
TECTOR.
CONNECTING
TO
POWER
SOURCE
OUTLET
This machine must be grounded while in use to protect
the operator from electric shock,
Plug power cord into a 110-120V properly grounded
type outlet protected by a 15-amp dual element time
deiay or Circuit breaker.
NOT ALL OUTLETS ARE PROPERLY GROUNDED.
IF YOU ARE NOT SURE THAT YOUR OUTLET, AS
PICTURED BELOW,
IS PROPERLY
GROUNDED,
HAVE IT CHECKED BY A QUAUFIED ELECTRICIAN.
WARNING: TO AVOID ELECTRIC SHOCK, DO NOT
TOUCH THE
METAL PRONGS
ON THE PLUG,
WHEN iNSTALLING OR REMOVING THE PLUG TO
OR FROM THE OUTLET.
WARNING: FAILURETO PROPERLY GROUNDTHIS
POWER TOOL CAN CAUSE ELECTRICUTION
OR
SERIOUS SHOCK. PARTICULARLY WHEN USED IN
DAMP LOCATIONS. OR NEAR METAL PLUMBING.
IF SHOCKED,
YOUR REACTION COULD CAUSE
YOUR HANDS TO HIT THE CUTTING TOOL.
IF POWER CORD IS WORN OR CUT, OR DAMAGED
IN ANY WAY, HAVE IT REPLACED IMMEDIATELY
TO AVOID SHOCK OR FIRE HAZARD.
3*PRONG
PLUG
'\
GROUNDING
PRONG
requirements
This power tool is equipped with a 3-conductor cord
and grounding type plug, approved by Underwriters'
Laboratories and the Canadian Standards Association.
The ground conductor has a green jacket and is at-
tached to the tool housing at one end and to the ground
prong in the attachment plug at the other end.
This plug requires a mating 3-conductor grounded type
outlet as shown.
If the outlet you are planning to use for this power tool
is of the two prong type, DO NOT REMOVE OR ALTER
THE GROUNDING
PRONG IN ANY MANNER. Use
an adapter as shown and always connect the grounding
lug to known ground.
It is recommended that you have a qualified electrician
replace the TWO prong outlet with a properly grounded
THREE prong outlet.
An adapter as shown below is available for connecting
plugs to 2-prong receptacles,
WARNING:
THE GREEN GROUNDING
LUG EX-
TENDING
FROM THE ADAPTER MUST BE CON-
NECTED TO A PERMANENT
GROUND SUCH AS
TO A PROPERLY GROUNDED OUTLET BOX.
GROUNDING
LUG
SCREW
\
//'_
",
X
2*PRONG
X
RECEPTACLE
ADAPTER
NOTE: The adapter illustrated is for use only if you
already have a properly grounded 2-prong receptacle.
Adapter is not allowed in Canada bythe Canadian Elec-
trical Code.
The use of any extension cord will cause some loss of
3ower. To keep this to a mmrmum and to prevent over-
qeating ano motor burn-out, use the table below to
determine the minimum wire s=ze (A.W.G.) extension
cora, Use only 3 wire extension cords which have 3-
prong grounding type plugs and 3-pole receptacles
which accept the tools p_ug.
ALWAYS USE A
PROPERLY
GROUNDED
OUTLET
Your unit is for use on 120 volts. It has a plug that looks
...................
like the one above.
0-25 Feet
26-50 Feet
51-100 Feet
Wire Size A.W.G.
16
14
t2