Hp Storage Server Management Console User Interface - HP StorageWorks X5000 Release Note

Hp proliant storage server with windows storage server 2003 r2 - release notes (5697-6073, october 2006)
Hide thumbs Also See for StorageWorks X5000:
Table of Contents

Advertisement

Workaround
Issue:
Installation of Insight Management Agent fails
Description
Workaround

HP Storage Server Management console user interface

This section describes issues with the user interface for the HP Storage Server Management console.
Issue:
HP Storage Server Management console stops responding after cancelling
Description
Workaround If the console is unresponsive, do the following:
Issue:
HP Storage Server Management console reports a DL100 G2 Data Protection Storage Server as a
DL100 G2 Storage Server
Description
Workaround None required. This does not effect the functionality or the software installed
Issue:
HP Storage Server Management console reports that Services for UNIX (SFU) 3.5 is installed on
the server after an upgrade to Windows Storage Server 2003 R2
R2 upgrade
The R2 upgrade process removes the drive letter of the DON'T ERASE volume,
which results in a different drive letter being assigned to the DVD drive. You
should change the DVD drive letter back to the originally assigned drive letter
and restart the upgrade process. To find the DVD drive letter at the time of the
upgrade and reassign it:
1.
Run regedit.exe.
2.
Navigating to the key "path" under HKEY_LOCAL_MACINE\SOFT-
WARE\Hewlett-Packard\R2Upgrade shows the DVD-ROM drive letter.
3.
Reassign the DVD-ROM letter to be the same as identified in the previous step.
The installation of the Insight Management Agent fails when upgrading to
Windows Storage Server 2003 R2. The c:\CPQSYSTEM\log\cpqsetup.log
states that the installation operation was not successful.
After the R2 upgrade has completed, remove the HP Management Agent using
Add or Remove Programs from the Control Panel. This requires a reboot of
the system. After the system has rebooted, set the operating system language
to English (if necessary). Install the management agent manually by opening
cp006033.exe located the UPDATES\PSP directory on your DVD drive.
HP Storage Server Management console user interface
After selecting HP Storage Server Management > Storage Management > Single
Instance Storage, the management console sometimes stops responding after
performing the following steps:
1.
Click on any data volume that does not have Single Instance Storage installed.
2.
Select the Install SIS action from the Actions pane or from the right-click menu.
3.
Click No when prompted about whether or not to continue.
1.
Run Task Manager (select Start, then Run, and type taskmgt.exe).
2.
Select the Applications tab.
3.
Select HP Storage Server Management.
4.
Click the End Task button.
5.
Click End Now when prompted.
After an upgrade to Windows Storage Server 2003 R2, a DL100 G2 Data
Protection Storage Server can identify itself in labels as a DL100 G2 Storage
Server.
on the server.
Storage Server with Windows Storage Server 2003 R2 release notes
Install SIS