Delta Resync Configuration - HP StorageWorks P9000 - Disk Arrays User Manual

Hp storageworks p9000 continuous access journal user guide (av400-96349, january 2011)
Hide thumbs Also See for StorageWorks P9000 - Disk Arrays:
Table of Contents

Advertisement

2.
Create a Continuous Access Synchronous pair on the primary system. See HP StorageWorks
P9000 Continuous Access Synchronous User Guide for instructions.
3.
When Continuous Access Synchronous pair status is PAIR, create the Continuous Access
Journal pair on the primary system. The mirror ID must be set between 1 and 3.

Delta resync configuration

In a Continuous Access Journal delta resync configuration, you create a second Continuous Access
Journal pair in a 3DC multitarget. The pair is created using the Continuous Access Synchronous
secondary volume (S-VOL) and the Continuous Access Journal S-VOL, as illustrated in the following.
The delta resync operation requires less time to bring the S-VOL to a consistent state after a failure
occurs because only missing differential data needs to be copied. The delta resync operation is
performed when the primary site fails, as illustrated in the Delta Resync in a Primary Site Disaster
figure (below).
Figure 21 3DC multitarget with delta resync
Two operations are performed for the delta resync configuration:
Create the Continuous Access Journal delta resync pair
In a primary site disaster, perform the delta resync operation
The delta resync system is created after setting up the main Continuous Access Synchronous and
Continuous Access Journal pairs in the multitarget configuration.
Data is not copied at the time you set up the delta resync pair. The primary volume (P-VOL)
and S-VOL in this system contain data – from their respective Continuous Access Synchronous
and Continuous Access Journal systems
If a failure on the primary site occurs, the Continuous Access Synchronous S-VOL is made the
primary production volume using the RAID Manager horctakeover command. Differential
data stored in the journal volumes is used to synchronize the S-VOL, via the pairresync
operation.
Figure 22 Delta resync in a primary site disaster
138 Continuous Access Journal configurations with Continuous Access Synchronous

Advertisement

Table of Contents
loading