Table 19 RAID Manager error codes for Continuous Access Journal (continued)
Error code (SSB1)
Error code (SSB2)
3720
3723
3726
3728
3729
372B
372C
372D
372E
8C13
8C19
8C1A
8C1B
8C20
8F00
8F10
Error content
A request by Cnt Ac-J Paircreate or Pairresync was rejected because the
journal volume in the specified master journal was blocked.
The Cnt Ac-J pair cannot be created because the version of the DKCMAIN
micro program on the remote storage system does not support the LUSE
volume.
The Cnt Ac-J pair cannot be created because the volume specified as the
P-VOL was the system disk.
A request of Cnt Ac-J Paircreate was rejected because it was connected
with the old model and the specified volume was unsupported.
A request of Cnt Ac-J Paircreate was received. However, the pair could not
share the volume with Continuous Access Synchronous because the Cont
Access Journal 3DC & 4x4 Open MF program product was not installed
in the primary system.
A pair cannot be created because the secondary system does not support
the combination of multiple primary and secondary systems.
The volume is inaccessible because the primary volume is blocked.
The specified volume is used in the system that consists of multiple primary
and secondary systems. Therefore the command was rejected because the
delta resync operation cannot be executed.
A request to create or resynchronize a pair in the system that consists of
multiple primary and secondary systems was rejected because the Cont
Access Journal 3DC & 4x4 Open MF program product was not installed
in the primary system.
Paircreate or Pairresync is not available, because the specified journal is
dedicated to the Cnt Ac-J-Continuous Access Synchronous combination
(2DC), and the MU# is 0.
The Cnt Ac-J pair cannot be created because the specified CTG number is
out of range of supporting.
The Cnt Ac-J pair cannot be created or resynchronized because the specified
journal number is incorrect.
The Cnt Ac-J pair cannot be created because the specified journal number
is out of range of supporting.
The request to update options was rejected because the specified journal
number or mirror ID is incorrect.
A request of Cnt Ac-J Paircreate was rejected because the specified volume
was the external volume.
The Cnt Ac-J pair cannot be created because the specified volume is part
of a Business Copy or Flash Copy pair.
Troubleshooting using RAID Manager