- The Range column shows Mirror for at least one of the above pairs.
To be able to continue processing, do either of the following:
- Ensure that the Range column shows LU for all pairs in the same mirror.
- In the Preview list, select one pair in one mirror, and then other pairs in the mirror is
excluded.
6.
From the Priority list, specify the scheduling order for resynchronizing selected pairs. If Range
is Mirror, the Priority list is disabled.
7.
The DKC box displays the following information:
The serial number with the LDKC number.
The controller ID with the model name.
The path type.
8.
The Resync Mode box indicates the type of pair resync that will take place when the operation
is executed.
Normal. The split pair whose status is PSUS or PSUE is recovered (resynchronized).
Delta. The delta resync operation is performed.
Return to standby. The pair status changes from HLDE to HOLD.
9.
In the Error Level list, select one of the following options to take place if a failure occurs during
resync. Note that if the Range option is set to Mirror, Error Level options are disabled.
Mirror, to cause all pairs in the failed pair's mirror to be split.
LU, to cause only the specified pair or pairs that failed to be split.
10. Click Set.
1 1. See the Preview list to check the settings that you have made.
If you want to modify a setting, select and right click the item in the Preview list and then
select Modify.
If you want to delete a item, select and right click the item in the Preview list and then
select Delete.
12. When satisfied, click Apply. This starts the operation. Verify the status when the operation is
completed. To monitor the progress of the operation, see
(page
67).
If an error occurs, right click the item in the Preview list error code and select Error Detail.
NOTE:
not change after you perform the delta resync operation, some of the requirements may not
have been fulfilled. Check pair status of the Continuous Access Synchronous pair, Continuous
Access Journal pair, and Continuous Access Journal pair for delta resync to make sure they
are in the required status for delta resync.

Resynchronize a mirror

When you resynchronize a mirror, the data copy from the master journal to the restore journal
restarts.
Prerequisite information
The resynchronize a mirror operation is performed from the primary storage system only.
Use the RAID Manager to restore a mirror when the consistency group contains multiple
journals (see
62
Pair operations
If the status of the Continuous Access Journal pair for delta resync operation does
Figure 5 (page
30),
Figure 6 (page
31), and
"Monitor pair activity and status"
Figure 7 (page
31)). The