Epson 610 Service Manual page 9

Seiko epson corporation. user guide color image scanner 610
Hide thumbs Also See for 610:
Table of Contents

Advertisement

EPSON Perfection 610

Number of hubs:
This device must be in the Tier 1 or 2 with a
recommended USB cable.
(Tier 1: Host - this device, Tier 2: Host - Hub -
this device)

Light source:
White cold cathode fluorescent lamp

Option:
None

Operate switch:
None

LED indicator:
None

Start button:
Ease of use with Page Manager

Scanning time:
Color A4, Pentium 300MHz
300 dpi: 60 seconds
600 dpi: 280 seconds
ELECTRICAL SPECIFICATIONS

Rated voltage:
AC100-120V or AC220-240V

Input voltage:
AC 100-120V 10% or AC 220-240V 10%

Rated current:
0.5A (Input AC 100V) or 0.3A (Input AC 200V)

Rated frequency range: 50-60Hz

Input frequency range:
49.5-60.5 Hz

Power consumption:
Approximately 20 W

Insulation resistance:
10 M
(between AC line and chassis)

Dielectric strength:
AC 1.5kV, 1 min
(between AC line and chassis)
SAFETY, EMC, EPA

Safety:
UL1950 (UL)
CSA C22.2 No.950 (CSA)
EN60950 (VDE)
IEC950 (ROTEST, PSB)
Product Description
at 500 VDC

EMC:

CE Marking:
Low Voltage Directive 73/23/EEC
EMC Directive 89/336/EEC

EPA:
RESISTANCE TO ELECTRIC NOISE

Static electricity:
ENVIRONMENTAL CONDITIONS

Temperature:

Humidity:
RELIABILITY

MCBF:
OPERATING CONDITIONS

Dust:

Illumination:
Specifications
FCC Part15 Subpart B Class B
CSA C108.8 Class B
AS/NZS3548 Class B
CISPR Pub22 Class B
CNS13438 Class B
EN60950
EN55022 Class B
EN61000-3-2
EN61000-3-3
EN50082-1
IEC 801-2/801-3/801-4
Energy Star Program
Panel:
10kV
Metal:
7kV / 150pF, 150
Operating: 5 C to 35 C
Storage:
-25 C to 60 C
Operating:
10 to 80%, no condensation
Storage:
10 to 85%, no condensation
10,000 cycles
Ordinary office or home conditions.
Extreme dust should be avoided.
Operation under direct sunlight or near strong
light source is not guaranteed and should be
avoided.
Revision B
9

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Perfection 610

Table of Contents