Epson 610 Service Manual page 24

Seiko epson corporation. user guide color image scanner 610
Hide thumbs Also See for 610:
Table of Contents

Advertisement

EPSON Perfection 610
Table 3-5. The carriage unit operates but the error is indicated.
Cause
Step
Checkpoints
The CR home
Check the signal levels
1
position sensor
between the collector (+)
is defective.
and emitter (-) of PC1. The
signal level should change
depending on the condition
below:
• HIGH (4.5V) = Light is
blocked in PC1.
• LOW (0.3V) = Light
passes in PC1.
Table 3-6. The lamp does not light up.
Cause
Step
Checkpoints
CN5 on the
1
Check that CN5 is
main board is
disconnected.
disconnected.
CN1 or CN2 on
2
Check that CN1 or CN2 on
the CCD sensor
the CCD sensor board is
board is
disconnected.
disconnected.
The connector
3
Check that the connector is
for the lamp is
properly connected to the
not properly
inverter board.
connected to
the inverter
board.
The lamp is
4
After replacing the lamp,
defective.
check that the lamp lights
up.
The inverter
5
After replacing the inverter
board is
board, check that the lamp
defective.
lights up.
The main board
6
---
is defective.
Troubleshooting
Finding
Remedy
---
Replace the CR
home position
sensor (PC1) on
the main board.
Finding
Remedy
Yes
Connect CN5 on
the main board
properly.
Yes
Connect CN1 or
CN2 on the CCD
sensor board
properly.
No
Connect the
connector
properly.
Yes
Replace the
lamp.
Yes
Replace the
inverter board.
---
Replace the main
board.
Troubleshooting
Table 3-7. Image is not read clearly.
Cause
Step
Checkpoints
Any mirror in the
1
After cleaning the mirror(s),
carriage unit or
check that image is read
the surface of
clearly.
the lamp is dirty.
The CCD
2
---
sensor board is
defective.
The main board
3
---
is defective.
Table 3-8. USB Interface Error
Cause
Step
Checkpoints
The host or O/S
1
On the Windows, access
(Windows'98/
My Computer > Property >
NT) does not
Device Manager, and
support USB.
check that Universal Serial
Bus Controller is effective.
The TWAIN
2
Check that the driver for
driver attached
the scanner is installed
for the scanner
properly.
is not properly
installed.
The USB cable
3
After replacing the USB
is defective.
cable, check that the error
is not indicated.
The main board
4
---
is defective.
Revision B
Finding
Remedy
No
Clean the
surface of the
lamp.
---
Replace the CCD
sensor board.
---
Replace the main
board.
Finding
Remedy
No
Replace the host.
No
Instal the correct
driver properly.
No
Replace the USB
cable.
---
Replace the main
board.
24