EPSON Perfection 610
1.6 Error Indications
Refer to Section 1.5 for the error indications.
COMMAND ERROR
Cause:
Undefined command is detected.
Disposition:
The scanner ignores a wrong command and
parameter(s), so it keeps the current settings or
default value effective. The scanner sends
NACK and waits for the next command and
parameter(s).
Indicator:
No effect
Remedy:
Error condition is cleared when the scanner
receives a correct command.
COMMUNICATION ERROR
Cause:
Wrong procedure is detected in the interface
communication.
USB cable was removed during communication.
Disposition:
The scanner stops the ongoing job.
Indicator:
The lamp starts blinking. (The lamp goes off in
30 minutes.)
Remedy:
Turn the scanner off and then back on.
Connect the USB cable again.
Acceptable command:
None
FATAL ERROR
Cause:
The lamp is broken.
The scanner is turned on before the
transportation lock is released.
System breakdown
Disposition:
The scanner stops the ongoing job.
Product Description
Indicator:
Remedy:
Acceptable command: [ESC F, ESC f, ESC @]
Error Indications
The lamp starts blinking. (The lamp goes off after
30 minutes.)
The lamp does not light up when it has blown.
(After the cause of the error is removed)
Turn the scanner off and then back on.
Connect the USB cable again.
Receiving of ESC@
Revision B