Maintenance Indicators

I The warning lights on the projector indicate problems inside the projector.
I If a problem occurs, either the TEMPERATURE WARNING indicator or the LAMP REPLACEMENT
indicator will illuminate red, and the power will turn off. After the power has been turned off, follow
the procedures given below.
POWER
indicator
About the TEMPERATURE WARNING indicator
If the temperature inside the projector in-
creases, due to blockage of the air vents, or
the setting location, "
lower left corner of the picture. If the tem-
perature keeps on rising, the lamp will turn
off and the TEMPERATURE WARNING in-
dicator will blink, the cooling fan will run for
further 90 seconds, then the power will be
shut off. After "
perform the following measures.
Maintenance indicator
Normal
TEMPERA-
TURE
WARNING
Off
indicator
Green on
Green
LAMP
REPLACE-
blinks
when the
MENT
lamp is
indicator
active.
Info
• If the TEMPERATURE WARNING indicator illuminates, and the power turns off, follow the above possible
solutions and then wait until the projector has cooled down completely before plugging in the power cord and
turning the power back on. (At least 5 minutes.)
• If the power is turned off and then turned on again, as during a brief test, the LAMP REPLACEMENT indica-
tor may be triggered, preventing the power from going on. Should this occur, take the power cord out of the
wall outlet and plug it back in again.
• If you want to clean the air vents during projector operation, be sure to first press
turned off and the cooling fan has stopped, then clean the vents.
• Do not unplug the power cord after the power has been turned off and while the cooling fan is running. The
cooling fan runs for about 90 seconds.
-70
" will blink in the
" appears, be sure to
Condition
Abnormal
Abnormal
The internal
temperature is
Red on/
abnormally high.
Power off
Red
Time to change
blinks
the lamp
Red on/
The lamp does
Power off
not illuminate.
About the
TEMPERATURE
LAMP
WARNING
REPLACEMENT
indicator
indicator
I When the lamp
LAMP
exceeds 1,900 cumulative hours
REPLACEMENT
of use, "
indicator
on the screen in yellow. When
the cumulative hours of use
reach 2,000, "
change to red, the lamp will au-
tomatically turn off and then the
projector as well. At this time, the
LAMP REPLACEMENT indica-
tor will illuminate in red.
I If you try to turn on the projector
a fourth time without replacing
the lamp, the projector will not
turn on.
Problem
• Blocked air intake
• Cooling fan break-
down
• Internal circuit failure
• Clogged air intake
• Lamp usage time
exceeded 1,900
hours
• Burnt-out lamp
• Lamp circuit failure
" will be displayed
Possible Solution
• Relocate the projector to an area
with proper ventilation.
• Take the projector to your nearest
Sharp Authorized Projector Dealer
or Service Center (see page 78)
for repair.
• Take the projector to your nearest
Sharp Authorized Projector Dealer
or Service Center (see page 78)
for repair or lamp replacement.
• Please exercise care when
replacing the lamp.
and after the power has
" will