Resetting The Air Filter Timer - Epson PowerLite 6100i User Manual

Epson powerlite 6100i multimedia projector user's guide
Hide thumbs Also See for PowerLite 6100i:
Table of Contents

Advertisement

note
If the air filter has been
stained by tobacco smoke, it
cannot be cleaned. Replace
the filter.
note
The air filter usage timer
shows 0H until you've used
the filter for at least 10
hours.
Maintaining the Projector
92
Follow these steps:
1. Turn off projector and unplug the power cord.
2. Turn projector upside down.
3. Remove the air filter by pushing down on the two tabs to
release them.
4. Remove the air filter by pulling the center of air filter straight out.
5. Insert the new air filter with the tab facing the front of the
projector.
6. Close the air filter cover.
7. Reset the air filter timer as described in the next section.

Resetting the Air Filter Timer

1. Plug the projector in and turn it on.
2. Press the
button on the remote control, select
Menu
from the Reset menu, then press
Filter Time
3. When you see the confirmation message, select
.
Enter
4. When you're finished, press
Enter
Yes
to exit the menu system.
Menu
Reset Air
.
, then press