Circuit Requirements For 220V; Grounding Requirements - Grizzly g0703 Owner's Manual

1 1/2 hp cyclone dust collector
Hide thumbs Also See for g0703:
Table of Contents

Advertisement

circuit requirements for 220v

This machine can be converted to operate on a
220V power supply. The intended 220V circuit
must have a verified ground and meet the require-
ments that follow:
nominal voltage .............................. 220v/240v
cycle ..........................................................60 hz
phase ........................................... single-phase
circuit rating ...................................... 15 amps
plug/receptacle ............................. nema 6-15

grounding requirements

This machine MUST be grounded. In the event
of certain malfunctions or breakdowns, grounding
reduces the risk of electric shock by providing a
path of least resistance for electric current.
For 110V operation: The plug specified under
"Circuit Requirements for 110V" on the previ-
ous page has a grounding prong that must be
attached to the equipment-grounding wire inside
the included power cord. The plug must only be
inserted into a matching receptacle (see below)
that is properly installed and grounded in accor-
dance with all local codes and ordinances.
GROUNDED
5-20 RECEPTACLE
Hot
Neutral
5-20 PLUG
Grounding Prong
figure 2. typical 5-20 plug and receptacle.
L5-30 GROUNDED
LOCKING
RECEPTACLE
Neutral
L5-30
LOCKING
PLUG
Hot
Grounding Prong
is Hooked
figure 3. typical l5-30 plug and receptacle.
Model g0703/g0703p (Mfg. Since 3/12)
For 220V operation: The plug specified under
"Circuit Requirements for 220V" on the previous
page has a grounding prong that must be attached
to the equipment-grounding wire on the included
power cord. The plug must only be inserted into
a matching receptacle (see following figure) that
is properly installed and grounded in accordance
with all local codes and ordinances.
GROUNDED
6-15 RECEPTACLE
Current Carrying Prongs
6-15 PLUG
Grounding Prong
figure 4. typical 6-15 plug and receptacle.
No adapter should be used with the
required plug. If the plug does not fit the
available receptacle, or the machine must
be reconnected for use on a different type
of circuit, the reconnection must be made
by a qualified electrician and comply with all
local codes and ordinances.
Serious injury could occur if you connect
the machine to power before completing the
setup process. DO NOT connect to power
until instructed later in this manual.