Modifying A Configuration; Saving And Restoring Iscsi Or Iscsi/Fcoe Controller Configurations; Restoring Iscsi Or Iscsi/Fcoe Module Configuration And Persistent Data - HP EVA P6000 User Manual

Enterprise virtual array
Hide thumbs Also See for EVA P6000:
Table of Contents

Advertisement

Modifying a configuration

The module has the following major areas of configuration:
Management port configuration requires the use of the following commands:
The
The
iSCSI port configuration requires using the following commands:
The
The
Virtual port groups configuration requires the following commands:
The
The
LUN mapping requires the use of the

Saving and restoring iSCSI or iSCSI/FCoE controller configurations

Saving and restoring a configuration helps protect your work. You can also use a saved
configuration as a template for configuring other modules.
Persistent data consists of system settings, virtual port group settings, LUN mappings, discovered
FC targets, and discovered iSCSI initiators. To save a module's configuration and persistent data:
1.
Generate a file (HP_StorageWorks_MEZ50_FRU.bin) containing the saved data (see page
2- 1 2) , by entering the fru save CLI command.
This command stores the file locally on the module in an FTP directory.
2.
Transfer the saved data from the iSCSI or iSCSI/FCoE module to a workstation by executing
an FTP utility on a workstation.
The following example shows an FTP transfer to get the saved module configuration data:
c:\> ftp 172.17.137.102
Connected to 172.17.137.102.
220 (none) FTP server (GNU inetutils 1.4.2) ready.
User (172.17.137.102:(none)): ftp
331 Guest login ok, type your name as password.
Password: ftp
230 Guest login ok, access restrictions apply.
ftp> bin
200 Type set to I.
ftp> get HP_StorageWorks_MEZ50_FRU.bin
200 PORT command successful.
150 Opening BINARY mode data connection for 'HP_StorageWorks_MEZ50_FRU.bin'
(6168 bytes).
226 Transfer complete.
ftp: 6168 bytes received in 0.00Seconds 6168000.00Kbytes/sec.
ftp> quit
221 Goodbye.

Restoring iSCSI or iSCSI/FCoE module configuration and persistent data

1.
Transfer the saved data from a workstation to the iSCSI or iSCSI/FCoE module by executing
an FTP utility on the workstation.
The following example shows an FTP transfer to put previously saved module configuration
data on the module:
c:\> ftp 172.17.137.102
Connected to 172.17.137.102.
220 (none) FTP server (GNU inetutils 1.4.2) ready.
User (172.17.137.102:(none)): ftp
331 Guest login ok, type your name as password.
"set mgmt command" (page 218)
"show mgmt command" (page 235)
"set iSCSI command" (page 217)
"show iSCSI command" (page 229)
"set VPGroups command" (page 221)
"show VPGroups command" (page 244)
"show lunmask command" (page
Working with iSCSI or iSCSI/FCoE module configurations 249